Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

56

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0536 # 13 Y:2003 13 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,072 $7,350 Not Implemented
MA0324 # 03 Y:1995 03 1995 USE OPTIMUM THICKNESS INSULATION $9,394 $10,179 Not Implemented
MA0324 # 07 Y:1995 07 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $855 $1,373 Not Implemented
MA0324 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,835 $1,500 Implemented
MA0324 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,424 $14,935 Implemented
MA0324 # 02 Y:1995 02 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,426 $9,200 Not Implemented
MA0324 # 01 Y:1995 01 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $53,561 $21,794 Not Implemented
MA0324 # 06 Y:1995 06 1995 USE RADIANT HEATER FOR SPOT HEATING $1,987 $1,300 Not Implemented
MA0299 # 05 Y:1994 05 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,707 $0 Not Implemented
MA0299 # 01 Y:1994 01 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $35,014 $102,795 Not Implemented
MA0299 # 02 Y:1994 02 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,797 $4,000 Not Implemented
MA0299 # 03 Y:1994 03 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $9,593 $1,526 Not Implemented
MA0299 # 04 Y:1994 04 1994 DISCONNECT BALLASTS $8,033 $411 Not Implemented
MA0299 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $597 $525 Not Implemented
MA0299 # 07 Y:1994 07 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,724 $0 Not Implemented
MA0299 # 08 Y:1994 08 1994 INSULATE BARE EQUIPMENT $4,792 $1,267 Not Implemented
MA0299 # 09 Y:1994 09 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,660 $5,030 Not Implemented
MA0299 # 10 Y:1994 10 1994 REPAIR OR REPLACE STEAM TRAPS $470 $1,396 Not Implemented
MA0299 # 11 Y:1994 11 1994 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $413 $1,650 Not Implemented
MA0203 # 05 Y:1991 05 1991 INSTALL SET-BACK TIMERS $642 $161 Implemented
MA0203 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,651 $32,018 Implemented
MA0203 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $778 $547 Implemented
MA0203 # 02 Y:1991 02 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $7,245 $2,182 Implemented
MA0203 # 01 Y:1991 01 1991 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $13,019 $8,029 Implemented
MA0146 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $5,452 $2,816 Implemented