Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

234

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0448 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,870 $5,000 Not Implemented
WI0448 # 05 Y:2003 05 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,558 $1,200 Not Implemented
WI0448 # 06 Y:2003 06 2003 ADJUST BURNERS FOR EFFICIENT OPERATION $962 $500 Not Implemented
WI0448 # 07 Y:2003 07 2003 INSTALL OCCUPANCY SENSORS $610 $300 Implemented
WI0448 # 08 Y:2003 08 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $509 $1,280 Not Implemented
WI0430 # 01 Y:2002 01 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $24,059 $25,000 Not Implemented
WI0430 # 02 Y:2002 02 2002 INSTALL OCCUPANCY SENSORS $6,072 $18,000 n/a
WI0430 # 03 Y:2002 03 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,938 $11,250 n/a
WI0430 # 04 Y:2002 04 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,916 $1,549 Not Implemented
WI0430 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $741 $0 Implemented
WI0430 # 06 Y:2002 06 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $689 $39 Implemented
WI0422 # 01 Y:2002 01 2002 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $107,793 $715,000 Not Implemented
WI0422 # 02 Y:2002 02 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $51,405 $31,028 Not Implemented
WI0422 # 03 Y:2002 03 2002 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL $37,726 $40,000 Not Implemented
WI0422 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,645 $21,689 Implemented
WI0422 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $328 $0 Not Implemented
WI0411 # 01 Y:2002 01 2002 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $15,331 $2,200 Implemented
WI0411 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,921 $15,527 Implemented
WI0411 # 03 Y:2002 03 2002 INSTALL OCCUPANCY SENSORS $6,222 $9,800 Implemented
WI0411 # 04 Y:2002 04 2002 INSTALL SPECTRAL REFLECTORS / DELAMP $5,203 $0 Implemented
WI0411 # 05 Y:2002 05 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,879 $1,996 Implemented
WI0411 # 06 Y:2002 06 2002 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,308 $8,000 Implemented
WI0411 # 07 Y:2002 07 2002 REPLACE CLOTH RAGS WITH PAPER TOWELS $3,427 $0 Not Implemented
WI0411 # 08 Y:2002 08 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,941 $740 Implemented
WI0411 # 09 Y:2002 09 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,654 $6,100 Not Implemented