Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
234
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0404 # 01 Y:2001 | 01 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $12,000 | $0 | Implemented |
WI0404 # 02 Y:2001 | 02 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,918 | $14,500 | Not Implemented |
WI0404 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $798 | $2,400 | Not Implemented |
WI0404 # 04 Y:2001 | 04 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $728 | $1,190 | Not Implemented |
WI0404 # 05 Y:2001 | 05 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $668 | $1,600 | Not Implemented |
WI0404 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $256 | $640 | Not Implemented |
WI0404 # 07 Y:2001 | 07 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $135 | $400 | Implemented |
WI0400 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $104,000 | $4,000 | Not Implemented |
WI0400 # 02 Y:2001 | 02 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,857 | $10,000 | Not Implemented |
WI0400 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $1,503 | $1,500 | Not Implemented |
WI0400 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $838 | $3,744 | Not Implemented |
WI0400 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $211 | $300 | Not Implemented |
WI0400 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,277 | $0 | Not Implemented |
WI0400 # 07 Y:2001 | 07 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $738 | $2,000 | Not Implemented |
WI0400 # 08 Y:2001 | 08 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $605 | $640 | Implemented |
WI0400 # 09 Y:2001 | 09 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $209 | $400 | Implemented |
WI0396 # 01 Y:2001 | 01 | 2001 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $172,934 | $560,000 | Not Implemented |
WI0396 # 02 Y:2001 | 02 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $40,600 | $10,000 | Not Implemented |
WI0396 # 03 Y:2001 | 03 | 2001 | USE A RAG RECYCLE SERVICE | $11,777 | $0 | Not Implemented |
WI0396 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $6,365 | $4,500 | Not Implemented |
WI0396 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,350 | $0 | Not Implemented |
WI0396 # 06 Y:2001 | 06 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,004 | $1,920 | Not Implemented |
WI0396 # 07 Y:2001 | 07 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,983 | $1,000 | Not Implemented |
WI0396 # 08 Y:2001 | 08 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143 | $30 | Not Implemented |
WI0341 # 01 Y:1999 | 01 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $40,755 | $0 | Not Implemented |