Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0787 # 10 Y:2008 | 10 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $388 | $1,000 | Implemented |
MI0170 # 01 Y:2008 | 01 | 2008 | INSULATE BARE EQUIPMENT | $61,285 | $976 | Implemented |
MI0170 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $17,359 | $3,320 | Implemented |
MI0170 # 03 Y:2008 | 03 | 2008 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,311 | $13,680 | Implemented |
MI0170 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,299 | $1,210 | Implemented |
MI0170 # 05 Y:2008 | 05 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,909 | $3,370 | Implemented |
MI0170 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,474 | $40 | Implemented |
MA0642 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,279 | $27,924 | Implemented |
MA0642 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,095 | $4,354 | Not Implemented |
MA0642 # 03 Y:2008 | 03 | 2008 | REDUCE VENTILATION AIR | $3,315 | $1,000 | Not Implemented |
MA0642 # 04 Y:2008 | 04 | 2008 | OPTIMIZE PLANT POWER FACTOR | $1,935 | $6,500 | Not Implemented |
MA0642 # 05 Y:2008 | 05 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,273 | $5,500 | Not Implemented |
MA0642 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $391 | $900 | Not Implemented |
MA0642 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $251 | $120 | Implemented |
SU0270 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,101 | $0 | Not Implemented |
SU0270 # 02 Y:2008 | 02 | 2008 | USE SYNTHETIC LUBRICANT | $952 | $0 | Not Implemented |
SU0270 # 03 Y:2008 | 03 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $48,133 | $1,453 | Implemented |
SU0270 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,122 | $129 | Implemented |
SU0270 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,799 | $1,379 | Implemented |
SU0270 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $393 | $175 | Implemented |
SU0270 # 07 Y:2008 | 07 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,234 | $18,896 | Implemented |
SU0270 # 08 Y:2008 | 08 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $392 | $430 | Implemented |
SU0270 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $259 | $317 | Implemented |
SU0270 # 10 Y:2008 | 10 | 2008 | OPTIMIZE PLANT POWER FACTOR | $2,250 | $2,850 | Implemented |
SU0270 # 11 Y:2008 | 11 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,767 | $22,925 | Implemented |