Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
378
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0099 # 02 Y:1997 | 02 | 1997 | OPERATE BOILERS ON HIGH FIRE SETTING | $1,495 | $1,495 | Implemented |
OD0099 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,007 | $11,490 | Implemented |
OD0099 # 03 Y:1997 | 03 | 1997 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $19,847 | $8,500 | Not Implemented |
NC0130 # 08 Y:1997 | 08 | 1997 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $22,291 | $28,000 | Not Implemented |
NC0130 # 07 Y:1997 | 07 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $9,082 | $5,200 | Not Implemented |
NC0130 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE COOLING WATER | $109,838 | $30,250 | Not Implemented |
NC0130 # 06 Y:1997 | 06 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $72,505 | $200 | Not Implemented |
NC0130 # 02 Y:1997 | 02 | 1997 | DISCONNECT BALLASTS | $474 | $750 | Not Implemented |
NC0130 # 10 Y:1997 | 10 | 1997 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,000 | $0 | Not Implemented |
NC0130 # 03 Y:1997 | 03 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,610 | $2,650 | Not Implemented |
NC0130 # 05 Y:1997 | 05 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $759 | $700 | Not Implemented |
NC0130 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $513 | $448 | Not Implemented |
NC0130 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,182 | $1,400 | Not Implemented |
MO0218 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $670 | $1,696 | Implemented |
MO0218 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $94 | $276 | Implemented |
MO0218 # 07 Y:1997 | 07 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,007 | $40 | Not Implemented |
MO0218 # 02 Y:1997 | 02 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $6,750 | $12,500 | Not Implemented |
MO0218 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,707 | $2,024 | Implemented |
MO0218 # 10 Y:1997 | 10 | 1997 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $480 | $800 | Not Implemented |
MO0218 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $185 | $115 | Implemented |
MO0218 # 01 Y:1997 | 01 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,045 | $3,500 | Implemented |
MO0218 # 09 Y:1997 | 09 | 1997 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $38,290 | $50,000 | Not Implemented |
MO0218 # 03 Y:1997 | 03 | 1997 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $6,400 | $15,000 | Implemented |
MO0217 # 03 Y:1997 | 03 | 1997 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $8,200 | $20,000 | Implemented |
MO0217 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $46,952 | $50,000 | Implemented |