Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
SIC 261 Pulp Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0365 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $17,614 $8,565 Implemented
WV0365 # 07 Y:2007 07 2007 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $9,063 $39,000 Not Implemented
WV0365 # 08 Y:2007 08 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,649 $9,450 Implemented
WV0365 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,552 $0 Implemented
WV0365 # 10 Y:2007 10 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,435 $0 Implemented
WV0365 # 11 Y:2007 11 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,863 $2,514 Implemented
LL0249 # 02 Y:2006 02 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $120,454 $320 Not Implemented
LL0249 # 04 Y:2006 04 2006 USE PHOTOCELL CONTROLS $85,337 $5,520 Not Implemented
LL0249 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $111,014 $18,240 Implemented
LL0249 # 06 Y:2006 06 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,963 $105 Not Implemented
LL0249 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $5,919 $1,740 Not Implemented
LL0249 # 08 Y:2006 08 2006 INSULATE BARE EQUIPMENT $2,138 $1,422 Not Implemented
LL0249 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,012 $4,200 Not Implemented
LL0249 # 01 Y:2006 01 2006 REPAIR AND ELIMINATE STEAM LEAKS $158,452 $8,830 Implemented
MS0291 # 08 Y:2006 08 2006 REPAIR AND ELIMINATE STEAM LEAKS $9,158 $169 Not Implemented
MS0291 # 09 Y:2006 09 2006 AIR CONDITION ONLY SPACE NECESSARY $6,088 $600 Not Implemented
MS0291 # 10 Y:2006 10 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $973 $0 Not Implemented
MS0291 # 07 Y:2006 07 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $10,794 $1,853 Implemented
MS0291 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,825 $34,509 Not Implemented
MS0291 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,397 $233 Implemented
MS0291 # 04 Y:2006 04 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $28,523 $2,000 Not Implemented
MS0291 # 03 Y:2006 03 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $38,212 $8,550 Not Implemented
MS0291 # 02 Y:2006 02 2006 RECOVER WASTE HEAT FROM EQUIPMENT $42,324 $29,520 Implemented
MS0291 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $224,456 $74,722 Not Implemented
NC0130 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $513 $448 Not Implemented