Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
372
matching recommendationsSIC | 262 | Paper Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0158 # 03 Y:1999 | 03 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $467 | $1,000 | Implemented |
WV0158 # 01 Y:1999 | 01 | 1999 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,912 | $1,000 | Implemented |
UD0539 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,296 | $0 | Implemented |
UD0539 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF CONDENSATE RETURNED | $8,880 | $15,000 | Implemented |
UD0539 # 01 Y:1998 | 01 | 1998 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $2,210 | $3,000 | Implemented |
MA0385 # 02 Y:1997 | 02 | 1997 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $131,859 | $311,500 | Implemented |
MA0385 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,568 | $31,829 | Implemented |
UD0502 # 05 Y:1996 | 05 | 1996 | USE LESS WASTEFUL PACKAGING | $48,400 | $0 | Implemented |
UD0502 # 04 Y:1996 | 04 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $19,538 | $500 | Implemented |
UD0502 # 02 Y:1996 | 02 | 1996 | OPTIMIZE PLANT POWER FACTOR | $29,345 | $93,000 | Implemented |
UD0502 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $372,300 | $800,000 | Implemented |
UD0500 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,461 | $3,112 | Implemented |
UD0500 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $25,819 | $30,000 | Implemented |
UD0500 # 10 Y:1996 | 10 | 1996 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $29,297 | $0 | Implemented |
UD0500 # 09 Y:1996 | 09 | 1996 | INSULATE BARE EQUIPMENT | $628 | $2,040 | Implemented |
UD0500 # 08 Y:1996 | 08 | 1996 | USE MINIMUM STEAM OPERATING PRESSURE | $4,188 | $0 | Implemented |
UD0500 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $30,899 | $1,000 | Implemented |
UD0500 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,054 | $200 | Implemented |
UD0500 # 05 Y:1996 | 05 | 1996 | MINIMIZE WATER USAGE | $14,124 | $0 | Implemented |
UD0500 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,011 | $1,380 | Implemented |
UD0500 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,228 | $3,710 | Implemented |
MA0362 # 01 Y:1996 | 01 | 1996 | USE EXISTING DAM TO GENERATE ELECTRICITY | $109,702 | $40,000 | Implemented |
MA0362 # 02 Y:1996 | 02 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $30,286 | $11,000 | Implemented |
MA0362 # 04 Y:1996 | 04 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $18,658 | $18,595 | Implemented |
MA0362 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,026 | $14,436 | Implemented |