Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

148

matching recommendations
Reset
SIC 262 Paper Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0462 # 07 Y:2000 07 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,757 $1,200 Implemented
MA0462 # 08 Y:2000 08 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,467 $14,000 Not Implemented
MA0462 # 09 Y:2000 09 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,406 $1,200 Implemented
MA0462 # 10 Y:2000 10 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $614 $3,575 Implemented
MA0456 # 01 Y:2000 01 2000 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $298,233 $84,000 Not Implemented
MA0456 # 02 Y:2000 02 2000 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $127,075 $218,000 Not Implemented
MA0456 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $37,815 $84,000 Implemented
MA0456 # 04 Y:2000 04 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $12,426 $0 Implemented
MA0456 # 05 Y:2000 05 2000 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $10,122 $16,000 Implemented
MA0456 # 06 Y:2000 06 2000 MINIMIZE WATER USAGE $8,467 $8,625 Implemented
MA0456 # 07 Y:2000 07 2000 REPAIR AND ELIMINATE STEAM LEAKS $3,929 $250 Implemented
MA0456 # 08 Y:2000 08 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $3,240 $5,500 Implemented
MA0456 # 09 Y:2000 09 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,914 $4,925 Implemented
MA0456 # 10 Y:2000 10 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,646 $4,225 Implemented
MA0456 # 11 Y:2000 11 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,457 $4,925 Implemented
MA0456 # 12 Y:2000 12 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,175 $3,400 Implemented
MA0385 # 01 Y:1997 01 1997 MODIFY MATERIAL APPLICATION METHODS $267,300 $50,000 Not Implemented
MA0385 # 02 Y:1997 02 1997 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $131,859 $311,500 Implemented
MA0385 # 03 Y:1997 03 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $52,705 $65,650 Not Implemented
MA0385 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,568 $31,829 Implemented
MA0385 # 05 Y:1997 05 1997 USE MAGNETIC TECHNOLOGY TO TREAT WATER $5,865 $10,640 Not Implemented
MA0385 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $729 $1,000 Not Implemented
MA0362 # 01 Y:1996 01 1996 USE EXISTING DAM TO GENERATE ELECTRICITY $109,702 $40,000 Implemented
MA0362 # 02 Y:1996 02 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $30,286 $11,000 Implemented
MA0362 # 03 Y:1996 03 1996 REPAIR OR REPLACE STEAM TRAPS $29,467 $6,350 Not Implemented