Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

742

matching recommendations
Reset
SIC 2621 Paper Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0201 # 03 Y:2002 03 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,132 $35,712 Not Implemented
MS0201 # 04 Y:2002 04 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,267 $340 Not Implemented
MS0201 # 05 Y:2002 05 2002 INSTALL TIMERS AND/OR THERMOSTATS $1,593 $1,063 Not Implemented
MA0488 # 07 Y:2001 07 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,800 $0 Implemented
MA0488 # 08 Y:2001 08 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,000 $12,000 Implemented
MA0488 # 09 Y:2001 09 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,900 $8,000 Implemented
MA0488 # 10 Y:2001 10 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,700 $7,500 Implemented
MA0488 # 11 Y:2001 11 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,000 $8,000 Not Implemented
MA0488 # 12 Y:2001 12 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,000 $8,000 Not Implemented
MA0488 # 13 Y:2001 13 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,900 $1,000 Not Implemented
MA0488 # 14 Y:2001 14 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $200 $150 Implemented
MA0488 # 01 Y:2001 01 2001 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $241,800 $250,000 Not Implemented
MA0488 # 02 Y:2001 02 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $84,500 $1,500 Implemented
MA0488 # 03 Y:2001 03 2001 MINIMIZE WATER USAGE $25,000 $0 Implemented
MA0488 # 04 Y:2001 04 2001 REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE $24,500 $5,000 Not Implemented
MA0488 # 05 Y:2001 05 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,500 $20,000 Not Implemented
MA0488 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,025 $700 Implemented
TA0009 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,587 $585 Not Implemented
TA0009 # 02 Y:2001 02 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,350 $0 Not Implemented
TA0009 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,597 $480 Implemented
TA0009 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $364 $0 Implemented
TA0009 # 05 Y:2001 05 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $233 $0 Implemented
TA0009 # 06 Y:2001 06 2001 USE POWER DURING OFF-PEAK PERIODS $210 $0 Implemented
TA0009 # 07 Y:2001 07 2001 USE SYNTHETIC LUBRICANT $158 $0 Not Implemented
TA0009 # 08 Y:2001 08 2001 INSTALL OCCUPANCY SENSORS $146 $160 Not Implemented