Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
136
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0123 # 07 Y:1998 | 07 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $5,200 | $100 | Not Implemented |
UM0123 # 08 Y:1998 | 08 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,161 | $200 | Not Implemented |
UD0496 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,040 | $1,500 | Implemented |
UD0496 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,270 | $5,000 | Not Implemented |
UD0496 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,005 | $30,000 | Not Implemented |
UD0496 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $365 | $1,720 | Implemented |
UD0496 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,485 | $18,550 | Not Implemented |
UD0494 # 01 Y:1996 | 01 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,517 | $14,000 | Implemented |
UD0494 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,890 | $0 | Not Implemented |
UD0494 # 03 Y:1996 | 03 | 1996 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,533 | $0 | Not Implemented |
UD0494 # 04 Y:1996 | 04 | 1996 | DISCONNECT BALLASTS | $1,437 | $1,650 | Implemented |
UD0494 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,632 | $12,454 | Implemented |
UD0494 # 06 Y:1996 | 06 | 1996 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $810 | $0 | Implemented |
UD0477 # 01 Y:1995 | 01 | 1995 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $1,927 | $0 | Implemented |
UD0477 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,045 | $4,000 | Implemented |
UD0477 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,867 | $5,759 | Implemented |
UD0477 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,444 | $4,300 | Implemented |
UD0477 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,196 | $21,000 | Implemented |
UD0477 # 06 Y:1995 | 06 | 1995 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,150 | $250 | Implemented |
UD0477 # 07 Y:1995 | 07 | 1995 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,625 | $600 | Not Implemented |
UD0477 # 08 Y:1995 | 08 | 1995 | RECOVER AND REUSE COOLING WATER | $10,234 | $2,500 | Not Implemented |
UD0477 # 09 Y:1995 | 09 | 1995 | RECOVER AND REUSE COOLING WATER | $16,375 | $7,500 | Implemented |
UD0464 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,874 | $15,000 | Not Implemented |
UD0464 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,302 | $0 | Not Implemented |
UD0464 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,152 | $3,000 | Not Implemented |