Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0641 # 04 Y:2002 | 04 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $17,780 | $20,000 | Not Implemented |
UD0641 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,888 | $59,307 | Not Implemented |
UD0641 # 06 Y:2002 | 06 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $15,849 | $22,500 | Not Implemented |
UD0641 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,676 | $22,800 | Implemented |
UD0641 # 08 Y:2002 | 08 | 2002 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $3,403 | $3,400 | Not Implemented |
UD0641 # 09 Y:2002 | 09 | 2002 | DISCONNECT BALLASTS | $2,709 | $1,968 | Not Implemented |
UD0641 # 10 Y:2002 | 10 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,588 | $2,500 | Implemented |
UD0641 # 11 Y:2002 | 11 | 2002 | INSTALL OCCUPANCY SENSORS | $2,180 | $121 | Not Implemented |
UD0641 # 12 Y:2002 | 12 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,957 | $9,969 | Implemented |
UD0641 # 13 Y:2002 | 13 | 2002 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,451 | $5,000 | Not Implemented |
UD0641 # 14 Y:2002 | 14 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,060 | $0 | Not Implemented |
UD0641 # 15 Y:2002 | 15 | 2002 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $673 | $1,275 | Not Implemented |
UM0211 # 01 Y:2002 | 01 | 2002 | BURN WASTE PAPER FOR HEAT | $25,568 | $92,625 | Not Implemented |
UM0211 # 02 Y:2002 | 02 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $10,900 | $4,200 | Implemented |
UM0211 # 03 Y:2002 | 03 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,317 | $2,352 | Implemented |
UM0211 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,138 | $3,838 | Implemented |
UM0211 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $718 | $100 | Implemented |
UM0211 # 06 Y:2002 | 06 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $543 | $500 | Implemented |
UM0211 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $520 | $375 | Implemented |
UM0211 # 08 Y:2002 | 08 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $441 | $200 | Not Implemented |
UM0211 # 09 Y:2002 | 09 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $383 | $600 | Implemented |
SF0233 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,975 | $0 | Implemented |
SF0233 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $450 | $890 | Not Implemented |
MI0027 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,448 | $1,859 | Implemented |
MI0027 # 02 Y:2002 | 02 | 2002 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $1,410 | $2,000 | Not Implemented |