Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KS2430 # 02 Y:2024 | 02 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,137 | $60 | n/a |
KS2430 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,174 | $9,216 | n/a |
KS2430 # 04 Y:2024 | 04 | 2024 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,172 | $5,121 | n/a |
KS2430 # 05 Y:2024 | 05 | 2024 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,954 | $60,601 | n/a |
KS2430 # 06 Y:2024 | 06 | 2024 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $93,352 | $684,000 | n/a |
KS2430 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $53,570 | $460,976 | n/a |
NC0349 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $3,668 | $1,000 | Not Implemented |
NC0349 # 02 Y:2006 | 02 | 2006 | REDUCE EXCESS STEAM BLEEDING | $23,110 | $13,525 | Not Implemented |
NC0349 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $18,045 | $2,000 | Not Implemented |
NC0349 # 04 Y:2006 | 04 | 2006 | INSULATE BARE EQUIPMENT | $2,375 | $1,000 | Not Implemented |
NC0349 # 05 Y:2006 | 05 | 2006 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $19,058 | $28,785 | Not Implemented |
NC0349 # 07 Y:2006 | 07 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,246 | $5,000 | Not Implemented |
NC0349 # 08 Y:2006 | 08 | 2006 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $5,891 | $4,000 | Not Implemented |
NC0349 # 06 Y:2006 | 06 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,087 | $4,340 | Not Implemented |
NC0256 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $174,891 | $550,000 | Not Implemented |
NC0256 # 02 Y:2003 | 02 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $21,031 | $45,000 | Not Implemented |
NC0256 # 03 Y:2003 | 03 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,507 | $500 | Implemented |
NC0256 # 04 Y:2003 | 04 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,417 | $12,587 | Not Implemented |
NC0256 # 05 Y:2003 | 05 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,851 | $30,000 | Not Implemented |
NC0256 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $2,112 | $4,375 | Implemented |
NC0256 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $123 | $200 | Implemented |
NC0256 # 08 Y:2003 | 08 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,260 | $28,000 | Implemented |
NC0256 # 09 Y:2003 | 09 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $60,400 | $20,000 | Implemented |
NC0256 # 10 Y:2003 | 10 | 2003 | MODIFY CURRENT INCENTIVE PROGRAM | $190,000 | $14,000 | Not Implemented |
NC0235 # 05 Y:2002 | 05 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $23,267 | $15,570 | Implemented |