Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0123 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,806 | $500 | Not Implemented |
UM0123 # 07 Y:1998 | 07 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $5,200 | $100 | Not Implemented |
UM0123 # 06 Y:1998 | 06 | 1998 | METER WASTE WATER | $599 | $900 | Not Implemented |
UM0123 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,709 | $6,300 | Not Implemented |
UM0123 # 01 Y:1998 | 01 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,378 | $2,188 | Not Implemented |
UM0123 # 04 Y:1998 | 04 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,138 | $4,120 | Not Implemented |
UD0496 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $365 | $1,720 | Implemented |
UD0496 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,005 | $30,000 | Not Implemented |
UD0496 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,270 | $5,000 | Not Implemented |
UD0496 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,040 | $1,500 | Implemented |
UD0496 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,485 | $18,550 | Not Implemented |
UD0494 # 01 Y:1996 | 01 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,517 | $14,000 | Implemented |
UD0494 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,890 | $0 | Not Implemented |
UD0494 # 03 Y:1996 | 03 | 1996 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,533 | $0 | Not Implemented |
UD0494 # 04 Y:1996 | 04 | 1996 | DISCONNECT BALLASTS | $1,437 | $1,650 | Implemented |
UD0494 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,632 | $12,454 | Implemented |
UD0494 # 06 Y:1996 | 06 | 1996 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $810 | $0 | Implemented |
UD0477 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,444 | $4,300 | Implemented |
UD0477 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,196 | $21,000 | Implemented |
UD0477 # 06 Y:1995 | 06 | 1995 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,150 | $250 | Implemented |
UD0477 # 07 Y:1995 | 07 | 1995 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,625 | $600 | Not Implemented |
UD0477 # 08 Y:1995 | 08 | 1995 | RECOVER AND REUSE COOLING WATER | $10,234 | $2,500 | Not Implemented |
UD0477 # 09 Y:1995 | 09 | 1995 | RECOVER AND REUSE COOLING WATER | $16,375 | $7,500 | Implemented |
UD0477 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,867 | $5,759 | Implemented |
UD0477 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,045 | $4,000 | Implemented |