Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

34

matching recommendations
Reset
SIC 2671 Paper Coated & Laminated, Packaging
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0597 # 03 Y:1996 03 1996 MINIMIZE WATER USAGE $62,640 $0 Not Implemented
GT0597 # 02 Y:1996 02 1996 OPERATE BOILERS ON HIGH FIRE SETTING $8,380 $2,000 Not Implemented
GT0597 # 01 Y:1996 01 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $9,934 $5,000 Not Implemented
GT0597 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,760 $48,450 Not Implemented
GT0597 # 05 Y:1996 05 1996 INSTALL COMMON HEADER ON COMPRESSORS $29,270 $96,000 Not Implemented
GT0597 # 04 Y:1996 04 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,570 $75,450 Not Implemented
BD0068 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,611 $2,563 Implemented
BD0068 # 08 Y:1996 08 1996 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $11,996 $9,045 Not Implemented
BD0068 # 07 Y:1996 07 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $562 $660 Not Implemented
BD0068 # 06 Y:1996 06 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,111 $1,020 Implemented
BD0068 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,531 $2,590 Implemented
BD0068 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $1,441 $1,500 Not Implemented
BD0068 # 02 Y:1996 02 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,590 $800 Implemented
BD0068 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,122 $12,270 Implemented
OR0276 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $324 $1,589 Not Implemented
UL0168 # 01 Y:1996 01 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $14,936 $1,400 Implemented
OR0276 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,184 $6,354 Implemented
UL0168 # 08 Y:1996 08 1996 USE EVAPORATION TO CONCENTRATE MATERIAL $16,800 $5,070 Implemented
UL0168 # 02 Y:1996 02 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $960 $40 Implemented
UL0168 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,464 $35 Implemented
UL0168 # 04 Y:1996 04 1996 OPTIMIZE PLANT POWER FACTOR $2,820 $7,774 Not Implemented
UL0168 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $459 $200 Not Implemented
UL0168 # 06 Y:1996 06 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $265 $265 Not Implemented
UL0168 # 07 Y:1996 07 1996 REGENERATE CLEANING SOLVENT ON-SITE AND REUSE $17,338 $3,000 Not Implemented
OR0276 # 03 Y:1996 03 1996 OPTIMIZE PLANT POWER FACTOR $216 $600 Not Implemented