Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
401
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0376 # 01 Y:2010 | 01 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $105,011 | $51,500 | Implemented |
BD0376 # 02 Y:2010 | 02 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,200 | $125 | Not Implemented |
BD0376 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,913 | $70,000 | Implemented |
BD0376 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $989 | $1,727 | Implemented |
NC0390 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $379 | $432 | Not Implemented |
NC0390 # 01 Y:2009 | 01 | 2009 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $46,662 | $67,500 | Not Implemented |
NC0390 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $871 | $100 | Implemented |
NC0390 # 03 Y:2009 | 03 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,075 | $0 | Not Implemented |
NC0390 # 04 Y:2009 | 04 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,533 | $50 | Implemented |
NC0390 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,223 | $50,369 | Not Implemented |
LE0286 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,921 | $25,494 | Implemented |
LE0286 # 08 Y:2009 | 08 | 2009 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,174 | $100 | Implemented |
LE0286 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,833 | $350 | Implemented |
LE0286 # 06 Y:2009 | 06 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,998 | $192 | Implemented |
LE0286 # 05 Y:2009 | 05 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,022 | $800 | Not Implemented |
LE0286 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,170 | $1,152 | Not Implemented |
LE0286 # 03 Y:2009 | 03 | 2009 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,875 | $10,000 | Not Implemented |
LE0286 # 02 Y:2009 | 02 | 2009 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $15,000 | $40,000 | Not Implemented |
LE0286 # 01 Y:2009 | 01 | 2009 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $20,166 | $9,360 | Not Implemented |
DL0032 # 01 Y:2008 | 01 | 2008 | REPLACE BOILER | $30,400 | $55,000 | Not Implemented |
DL0032 # 02 Y:2008 | 02 | 2008 | REDUCE VENTILATION AIR | $19,700 | $1,200 | Implemented |
DL0032 # 03 Y:2008 | 03 | 2008 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $12,400 | $7,000 | Not Implemented |
DL0032 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,639 | $31,781 | Implemented |
DL0032 # 06 Y:2008 | 06 | 2008 | REPLACE BOILER | $6,100 | $6,100 | Implemented |
DL0032 # 08 Y:2008 | 08 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $2,065 | $0 | Implemented |