Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
401
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0032 # 07 Y:2008 | 07 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,521 | $643 | Implemented |
DL0032 # 08 Y:2008 | 08 | 2008 | USE MINIMUM STEAM OPERATING PRESSURE | $2,065 | $0 | Implemented |
SD0405 # 01 Y:2008 | 01 | 2008 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $117,665 | $1,117,600 | Implemented |
SD0405 # 02 Y:2008 | 02 | 2008 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $62,965 | $69,500 | Implemented |
SD0405 # 03 Y:2008 | 03 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,824 | $22,665 | Implemented |
SD0405 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,507 | $900 | Implemented |
SD0405 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,660 | $4,270 | Implemented |
SD0405 # 06 Y:2008 | 06 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,270 | $4,650 | Not Implemented |
SD0405 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,436 | $3,324 | Not Implemented |
SD0405 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,411 | $3,110 | Not Implemented |
SD0405 # 09 Y:2008 | 09 | 2008 | INSTALL OCCUPANCY SENSORS | $606 | $256 | Implemented |
UF0408 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,980 | $15,208 | Not Implemented |
UF0408 # 02 Y:2008 | 02 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,404 | $870 | Implemented |
UF0408 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,339 | $1,246 | Implemented |
UF0408 # 04 Y:2008 | 04 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $187 | $0 | Not Implemented |
UF0408 # 05 Y:2008 | 05 | 2008 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,753 | $1,551 | Not Implemented |
UF0408 # 06 Y:2008 | 06 | 2008 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $44,425 | $3,443 | Not Implemented |
UF0408 # 07 Y:2008 | 07 | 2008 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $2,931 | $0 | Implemented |
LE0256 # 01 Y:2007 | 01 | 2007 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $101,767 | $50,000 | Not Implemented |
LE0256 # 02 Y:2007 | 02 | 2007 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $15,602 | $5,000 | Not Implemented |
LE0256 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,536 | $15,000 | Not Implemented |
LE0256 # 04 Y:2007 | 04 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,965 | $35,200 | Implemented |
LE0256 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $4,138 | $5,000 | Not Implemented |
LE0256 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,217 | $500 | Implemented |
LE0256 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $689 | $500 | Not Implemented |