Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsSIC | 2676 | Sanitary Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0056 # 07 Y:2016 | 07 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $356 | $170 | Not Implemented |
IP0056 # 08 Y:2016 | 08 | 2016 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $3,273 | $2,406 | Not Implemented |
NC0519 # 04 Y:2014 | 04 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $21,819 | $2,200 | Implemented |
NC0519 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,850 | $500 | Implemented |
NC0519 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $67,692 | $258,028 | Implemented |
NC0519 # 13 Y:2014 | 13 | 2014 | INSTALL OCCUPANCY SENSORS | $792 | $2,118 | Not Implemented |
NC0519 # 11 Y:2014 | 11 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $664 | $72 | Not Implemented |
NC0519 # 07 Y:2014 | 07 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,436 | $10,000 | Not Implemented |
NC0519 # 09 Y:2014 | 09 | 2014 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,308 | $2,500 | Not Implemented |
NC0519 # 08 Y:2014 | 08 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,811 | $17,150 | Not Implemented |
NC0519 # 03 Y:2014 | 03 | 2014 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $104,811 | $52,500 | Implemented |
NC0519 # 12 Y:2014 | 12 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $160 | Not Implemented |
NC0519 # 10 Y:2014 | 10 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,323 | $4,256 | Not Implemented |
NC0519 # 02 Y:2014 | 02 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $75,916 | $5,100 | Not Implemented |
NC0519 # 01 Y:2014 | 01 | 2014 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $207,427 | $102,000 | Implemented |
OK0858 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,791 | $1,220 | Not Implemented |
OK0858 # 02 Y:2013 | 02 | 2013 | INSTALL SET-BACK TIMERS | $1,493 | $172 | Not Implemented |
OK0858 # 08 Y:2013 | 08 | 2013 | DISCONNECT BALLASTS | $6,565 | $3,020 | Not Implemented |
OK0858 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,717 | $66,757 | Not Implemented |
OK0858 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,454 | $63,252 | Not Implemented |
OK0858 # 05 Y:2013 | 05 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $32,018 | $268,800 | Not Implemented |
OK0858 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $804 | $1,338 | Implemented |
OK0858 # 03 Y:2013 | 03 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,082 | $19,800 | Not Implemented |
OK0858 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $40,042 | $20,360 | Not Implemented |
MI0231 # 11 Y:2012 | 11 | 2012 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,120 | $1,498 | Not Implemented |