Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0273 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,216 | $3,300 | Not Implemented |
ND0273 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $355 | $715 | Implemented |
ND0273 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54 | $1,125 | Not Implemented |
ND0273 # 04 Y:1997 | 04 | 1997 | INSTALL OCCUPANCY SENSORS | $97 | $400 | Not Implemented |
ND0273 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,271 | $688 | Implemented |
ND0273 # 06 Y:1997 | 06 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,873 | $1,155 | Not Implemented |
ND0273 # 07 Y:1997 | 07 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $116,808 | $15,230 | Implemented |
ND0273 # 08 Y:1997 | 08 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $51,750 | $3,780 | Implemented |
ND0273 # 09 Y:1997 | 09 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $82 | $395 | Implemented |
ND0273 # 10 Y:1997 | 10 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $82 | $350 | Not Implemented |
ND0273 # 11 Y:1997 | 11 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,719 | $5,060 | Implemented |
ND0273 # 12 Y:1997 | 12 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $126 | $0 | Not Implemented |
OD0084 # 01 Y:1997 | 01 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,338 | $25,270 | Not Implemented |
OD0084 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $818 | $589 | Implemented |
OD0084 # 03 Y:1997 | 03 | 1997 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,617 | $4,378 | Not Implemented |
OD0084 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,487 | $1,724 | Implemented |
OD0084 # 05 Y:1997 | 05 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,624 | $1,495 | Implemented |
OD0084 # 06 Y:1997 | 06 | 1997 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,546 | $1,110 | Not Implemented |
OD0084 # 07 Y:1997 | 07 | 1997 | BURN WASTE OIL FOR HEAT | $2,284 | $3,402 | Not Implemented |
OD0084 # 08 Y:1997 | 08 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $28,563 | $11,432 | Implemented |
AR0115 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,924 | $1,110 | Implemented |
AR0115 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $593 | $593 | Implemented |
AR0115 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,749 | $210 | Implemented |
AR0115 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $735 | $15 | Implemented |
AR0115 # 05 Y:1997 | 05 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $591 | $500 | Not Implemented |