Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,451

matching recommendations
Reset
SIC 275 Commercial Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0139 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,567 $600 Implemented
NV0139 # 02 Y:1999 02 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $5,129 $0 Implemented
NV0139 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,871 $4,148 Implemented
UD0584 # 01 Y:1999 01 1999 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $28,107 $3,150 Implemented
UD0584 # 02 Y:1999 02 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $998 $1,200 Implemented
UD0584 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $981 $356 Implemented
SF0168 # 01 Y:1999 01 1999 INSTALL TIMERS AND/OR THERMOSTATS $3,158 $1,318 Implemented
SF0168 # 02 Y:1999 02 1999 INSTALL OCCUPANCY SENSORS $547 $1,344 Implemented
SF0168 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $482 $1,433 Implemented
NV0129 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $154 $225 Implemented
NV0129 # 02 Y:1999 02 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $230 $0 Implemented
NV0129 # 05 Y:1999 05 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $660 $400 Implemented
NV0127 # 01 Y:1999 01 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $704 $1,500 Implemented
NV0127 # 04 Y:1999 04 1999 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,768 $588 Implemented
NV0127 # 08 Y:1999 08 1999 USE RADIANT HEATER FOR SPOT HEATING $3,636 $4,525 Implemented
NV0127 # 10 Y:1999 10 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $1,343 $325 Implemented
BD0130 # 02 Y:1999 02 1999 USE RADIANT HEATER FOR SPOT HEATING $3,506 $2,000 Implemented
BD0130 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,416 $1,614 Implemented
BD0130 # 07 Y:1999 07 1999 RECOVER AND REUSE COOLING WATER $1,453 $2,410 Implemented
OD0127 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,954 $5,472 Implemented
OD0127 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN WATER LINES AND VALVES $3,582 $240 Implemented
OD0127 # 04 Y:1999 04 1999 COMBINE UTILITY METERS $9,570 $5,000 Implemented
SF0157 # 01 Y:1999 01 1999 INSTALL OCCUPANCY SENSORS $1,834 $1,456 Implemented
SF0157 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,418 $45,400 Implemented
SF0157 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $396 $2,106 Implemented