Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,445

matching recommendations
Reset
SIC 275 Commercial Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0131 # 19 Y:1984 19 1984 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $113 $39 Implemented
TS0003 # 01 Y:1984 01 1984 MINIMIZE WATER USAGE $3,197 $6 Implemented
TS0003 # 02 Y:1984 02 1984 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,050 $1,400 Implemented
TS0003 # 05 Y:1984 05 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,190 $400 Implemented
TS0003 # 06 Y:1984 06 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,500 $500 Implemented
OK0141 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $233 $325 Implemented
OK0141 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,645 $361 Implemented
OK0141 # 04 Y:1984 04 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $48 $70 Implemented
OK0141 # 05 Y:1984 05 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $756 $332 Implemented
KU0120 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,272 $2,159 Implemented
KU0120 # 04 Y:1984 04 1984 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $917 $0 Implemented
KU0120 # 05 Y:1984 05 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,077 $70 Implemented
KU0120 # 08 Y:1984 08 1984 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $249 $0 Implemented
GT0183 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,660 $200 Implemented
GT0183 # 02 Y:1983 02 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,680 $11,600 Implemented
GT0183 # 03 Y:1983 03 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,850 $9,000 Implemented
GT0183 # 06 Y:1983 06 1983 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $580 $360 Implemented
GT0183 # 07 Y:1983 07 1983 INSTALL TIMERS AND/OR THERMOSTATS $2,200 $909 Implemented
KU0084 # 03 Y:1983 03 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $877 $155 Implemented
KU0084 # 04 Y:1983 04 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $167 $160 Implemented
KU0070 # 05 Y:1983 05 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,975 $13,000 Implemented
KU0070 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $664 $42 Implemented
OK0070 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,791 $60 Implemented
OK0070 # 02 Y:1983 02 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $297 $392 Implemented
OK0070 # 05 Y:1983 05 1983 INSTALL SET-BACK TIMERS $4,660 $14,963 Implemented