IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,301

matching recommendations
Reset
SIC 275 Commercial Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0392 # 06 Y:2015 06 2015 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $606 $100 Implemented
SU0392 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $464 $223 Implemented
SU0392 # 08 Y:2015 08 2015 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $251 $654 Implemented
SU0392 # 09 Y:2015 09 2015 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $108 $281 Implemented
SU0392 # 10 Y:2015 10 2015 REDUCE VENTILATION AIR $234 $794 Implemented
SU0392 # 11 Y:2015 11 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,745 $8,154 Implemented
OK0920 # 01 Y:2015 01 2015 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $11,299 $3,815 Not Implemented
OK0920 # 02 Y:2015 02 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $2,194 $0 Not Implemented
OK0920 # 03 Y:2015 03 2015 INSTALL SET-BACK TIMERS $2,270 $1,550 Not Implemented
OK0920 # 04 Y:2015 04 2015 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $820 $3,450 Not Implemented
OK0920 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,796 $15,971 Not Implemented
OK0920 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $5,218 Not Implemented
OK0920 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,921 $2,360 Not Implemented
OK0920 # 08 Y:2015 08 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,051 $0 Not Implemented
OK0920 # 09 Y:2015 09 2015 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,138 $18,243 Not Implemented
OK0920 # 10 Y:2015 10 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,980 $1,500 Not Implemented
OK0920 # 11 Y:2015 11 2015 OPTIMIZE PLANT POWER FACTOR $3,157 $20,000 Not Implemented
OK0920 # 12 Y:2015 12 2015 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,000 $65,000 Not Implemented
OK0920 # 13 Y:2015 13 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $487 $476 Not Implemented
MI0281 # 01 Y:2015 01 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $26,495 $1,660 Implemented
MI0281 # 02 Y:2015 02 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $20,275 $240 Implemented
MI0281 # 03 Y:2015 03 2015 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $9,053 $24,488 Implemented
MI0281 # 04 Y:2015 04 2015 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,952 $2,400 Implemented
MI0281 # 05 Y:2015 05 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,141 $1,020 Not Implemented
MI0281 # 06 Y:2015 06 2015 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $3,624 $4,636 Implemented