Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
822
matching recommendationsSIC | 2752 | Commercial Printing, Lithographic |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0708 # 05 Y:2005 | 05 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $37,832 | $13,050 | Implemented |
OK0708 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,450 | $26,280 | Implemented |
OK0708 # 07 Y:2005 | 07 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $5,070 | $700 | Implemented |
UD0717 # 01 Y:2005 | 01 | 2005 | INCREASE USE OF AUTOMATION | $68,000 | $145,000 | Implemented |
UD0717 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,783 | $39,200 | Implemented |
UD0717 # 04 Y:2005 | 04 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $12,702 | $5,400 | Implemented |
UD0717 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,225 | $0 | Implemented |
UD0717 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,553 | $11,448 | Implemented |
UD0717 # 09 Y:2005 | 09 | 2005 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,658 | $2,526 | Implemented |
UD0705 # 01 Y:2004 | 01 | 2004 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $50,000 | $50,000 | Implemented |
UD0705 # 03 Y:2004 | 03 | 2004 | REDUCE SCRAP PRODUCTION | $12,990 | $0 | Implemented |
UD0705 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,683 | $0 | Implemented |
UD0705 # 09 Y:2004 | 09 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $1,214 | $0 | Implemented |
UD0705 # 10 Y:2004 | 10 | 2004 | COVER OPEN TANKS | $710 | $0 | Implemented |
UD0705 # 11 Y:2004 | 11 | 2004 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $83 | $0 | Implemented |
UD0703 # 01 Y:2004 | 01 | 2004 | REDUCE SCRAP PRODUCTION | $45,630 | $650 | Implemented |
UD0703 # 02 Y:2004 | 02 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $5,110 | $0 | Implemented |
UD0703 # 04 Y:2004 | 04 | 2004 | REDUCE OR ELIMINATE WASTE | $1,365 | $1,960 | Implemented |
UD0703 # 08 Y:2004 | 08 | 2004 | DISCONNECT BALLASTS | $392 | $206 | Implemented |
UD0703 # 10 Y:2004 | 10 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $289 | $126 | Implemented |
IA0342 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $775 | $344 | Implemented |
IA0342 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $1,094 | $888 | Implemented |
IA0342 # 04 Y:2004 | 04 | 2004 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,701 | $1,500 | Implemented |
IA0342 # 06 Y:2004 | 06 | 2004 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $7,150 | $715 | Implemented |
SU0186 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,704 | $0 | Implemented |