Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
82
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0041 # 04 Y:2019 | 04 | 2019 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,670 | $100 | Implemented |
NL0041 # 08 Y:2019 | 08 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $197 | $674 | Implemented |
NL0041 # 02 Y:2019 | 02 | 2019 | OPTIMIZE PLANT POWER FACTOR | $10,636 | $52,000 | Implemented |
NL0041 # 07 Y:2019 | 07 | 2019 | REPAIR AND ELIMINATE STEAM LEAKS | $2,123 | $200 | Implemented |
NL0041 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,751 | $600 | Implemented |
NL0041 # 01 Y:2019 | 01 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $238,833 | $700,000 | Implemented |
NL0031 # 03 Y:2019 | 03 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,344 | $46,600 | Implemented |
NL0031 # 02 Y:2019 | 02 | 2019 | INSTALL TURBULATORS | $66,132 | $93,000 | Implemented |
NL0031 # 01 Y:2019 | 01 | 2019 | USE OPTIMUM TEMPERATURE | $1,023,132 | $178,000 | Implemented |
NL0031 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,390 | $24,394 | Implemented |
NL0031 # 05 Y:2019 | 05 | 2019 | REPAIR AND ELIMINATE STEAM LEAKS | $5,225 | $1,600 | Not Implemented |
IA0183 # 09 Y:1997 | 09 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $11,440 | $50,000 | Not Implemented |
IA0183 # 08 Y:1997 | 08 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $17,122 | $4,200 | Implemented |
IA0183 # 07 Y:1997 | 07 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $315 | $0 | Not Implemented |
IA0183 # 06 Y:1997 | 06 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,112 | $600 | Implemented |
IA0183 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,639 | $8,400 | Implemented |
IA0183 # 04 Y:1997 | 04 | 1997 | RECOVER AND REUSE COOLING WATER | $6,010 | $5,809 | Not Implemented |
IA0183 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $1,081 | $798 | Not Implemented |
IA0183 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,353 | $3,856 | Implemented |
IA0183 # 01 Y:1997 | 01 | 1997 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $6,078 | $68,000 | Implemented |
IA0071 # 11 Y:1993 | 11 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $310 | $520 | Not Implemented |
IA0071 # 10 Y:1993 | 10 | 1993 | REPAIR OR REPLACE STEAM TRAPS | $688 | $1,980 | Implemented |
IA0071 # 09 Y:1993 | 09 | 1993 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,737 | $25,000 | Implemented |
IA0071 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $501 | $612 | Not Implemented |
IA0071 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,546 | $6,061 | Implemented |