Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
112
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0394 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,706 | $19,737 | Not Implemented |
NC0394 # 04 Y:2009 | 04 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,909 | $6,600 | Not Implemented |
NC0394 # 05 Y:2009 | 05 | 2009 | RECOVER AND REUSE COOLING WATER | $4,517 | $3,850 | Not Implemented |
WV0383 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,141 | $200 | Not Implemented |
WV0383 # 02 Y:2008 | 02 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $5,179 | $7,500 | Not Implemented |
WV0383 # 01 Y:2008 | 01 | 2008 | REDUCE VENTILATION AIR | $13,257 | $5,000 | Not Implemented |
WV0383 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $4,983 | $9,450 | Implemented |
WV0383 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,055 | $50 | Not Implemented |
WV0383 # 05 Y:2008 | 05 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,337 | $1,049 | Not Implemented |
WV0383 # 12 Y:2008 | 12 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $380 | $800 | Implemented |
WV0383 # 11 Y:2008 | 11 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $655 | $0 | Implemented |
WV0383 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $1,008 | $375 | Implemented |
WV0383 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $742 | $1,995 | Implemented |
WV0383 # 09 Y:2008 | 09 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,006 | $2,125 | Not Implemented |
WV0383 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,268 | $260 | Implemented |
NC0383 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,043 | $6,150 | Not Implemented |
NC0383 # 06 Y:2008 | 06 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,245 | $20,000 | Not Implemented |
NC0383 # 04 Y:2008 | 04 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $19,037 | $30,000 | Not Implemented |
NC0383 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,558 | $50,000 | Implemented |
NC0383 # 05 Y:2008 | 05 | 2008 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $4,551 | $10,000 | Implemented |
NC0383 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,848 | $50 | Not Implemented |
NC0383 # 10 Y:2008 | 10 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $11,700 | $11,589 | Implemented |
NC0383 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,623 | $100 | Implemented |
NC0383 # 02 Y:2008 | 02 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $38,474 | $0 | Implemented |
NC0383 # 01 Y:2008 | 01 | 2008 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $16,582 | $1,000 | Implemented |