Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,092
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0183 # 08 Y:1997 | 08 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $17,122 | $4,200 | Implemented |
IA0183 # 09 Y:1997 | 09 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $11,440 | $50,000 | Not Implemented |
CO0398 # 04 Y:1997 | 04 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $530 | $0 | Not Implemented |
CO0398 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $41,400 | $250,000 | Not Implemented |
CO0398 # 06 Y:1997 | 06 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $28,000 | $6,280 | Not Implemented |
CO0398 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,070 | $4,710 | Not Implemented |
CO0398 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $59 | $125 | Not Implemented |
CO0398 # 03 Y:1997 | 03 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,370 | $11,080 | Not Implemented |
NC0111 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $21,132 | $6,877 | Not Implemented |
NC0111 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $245 | $233 | Not Implemented |
NC0111 # 03 Y:1997 | 03 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $83 | $94 | Implemented |
NC0111 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $555 | $55 | Implemented |
NC0111 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $337 | $986 | Not Implemented |
NC0111 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $140 | $125 | Not Implemented |
NC0111 # 07 Y:1997 | 07 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,289 | $5,200 | Implemented |
NC0111 # 08 Y:1997 | 08 | 1997 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $76,000 | $0 | Not Implemented |
UD0528 # 01 Y:1997 | 01 | 1997 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $4,108 | $0 | Implemented |
UD0528 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,857 | $10,000 | Implemented |
UD0528 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,076 | $5,818 | Implemented |
UD0528 # 04 Y:1997 | 04 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,886 | $200 | Implemented |
UD0528 # 05 Y:1997 | 05 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,859 | $11,000 | Not Implemented |
OK0531 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $21,470 | $0 | Not Implemented |
OK0531 # 02 Y:1997 | 02 | 1997 | DISCONNECT BALLASTS | $1,079 | $500 | Implemented |
OK0531 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $631 | $1,870 | Not Implemented |
OK0531 # 04 Y:1997 | 04 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,000 | $0 | Implemented |