Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
344
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0854 # 06 Y:2008 | 06 | 2008 | REDUCE EXCESSIVE BOILER BLOWDOWN | $4,690 | $0 | Not Implemented |
GT0854 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,990 | $80,000 | Not Implemented |
GT0854 # 04 Y:2008 | 04 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $25,424 | $5,000 | Implemented |
GT0854 # 03 Y:2008 | 03 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,970 | $2,500 | Not Implemented |
GT0854 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,745 | $3,000 | Implemented |
GT0854 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,568 | $700 | Implemented |
GT0833 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $36,891 | $62,250 | Not Implemented |
GT0833 # 07 Y:2006 | 07 | 2006 | PAY BILLS ON TIME TO AVOID LATE FEES | $6,204 | $0 | Implemented |
GT0833 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,653 | $550 | Not Implemented |
GT0833 # 05 Y:2006 | 05 | 2006 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $29,400 | $0 | Implemented |
GT0833 # 04 Y:2006 | 04 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,806 | $18,000 | Not Implemented |
GT0833 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,153 | $0 | Not Implemented |
GT0833 # 02 Y:2006 | 02 | 2006 | ELIMINATE/REDUCE AN OPERATION | $137,445 | $0 | Not Implemented |
GT0833 # 01 Y:2006 | 01 | 2006 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $870,069 | $100,000 | Not Implemented |
GT0822 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $97,628 | $18,865 | Implemented |
GT0822 # 01 Y:2006 | 01 | 2006 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $22,995 | $640 | Implemented |
GT0822 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,292 | $10,800 | Not Implemented |
GT0822 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,620 | $850 | Not Implemented |
GT0822 # 06 Y:2006 | 06 | 2006 | COMBINE UTILITY METERS | $4,697 | $0 | Not Implemented |
GT0822 # 07 Y:2006 | 07 | 2006 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $450,000 | $20,000 | Implemented |
GT0822 # 05 Y:2006 | 05 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $60,069 | $87,937 | Not Implemented |
GT0820 # 05 Y:2006 | 05 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,650 | $5,952 | Not Implemented |
GT0820 # 04 Y:2006 | 04 | 2006 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $4,073 | $10,200 | Not Implemented |
GT0820 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,732 | $1,390 | Not Implemented |
GT0820 # 02 Y:2006 | 02 | 2006 | USE PHOTOCELL CONTROLS | $15,359 | $12,000 | Not Implemented |