Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

311

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0215 # 01 Y:2001 01 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,150 $1,000 Not Implemented
NC0215 # 02 Y:2001 02 2001 AIR CONDITION ONLY SPACE NECESSARY $1,330 $4,000 Not Implemented
NC0215 # 03 Y:2001 03 2001 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $91 $65 Not Implemented
NC0215 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $93 $100 Implemented
NC0215 # 05 Y:2001 05 2001 USE ULTRASONIC CLEANING $19,642 $5,000 Not Implemented
NC0215 # 06 Y:2001 06 2001 $240,000 $270,000 Not Implemented
NC0211 # 01 Y:2001 01 2001 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $23,426 $20,000 Implemented
NC0211 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,719 $800 Implemented
NC0211 # 03 Y:2001 03 2001 USE MINIMUM STEAM OPERATING PRESSURE $2,014 $250 Implemented
NC0211 # 04 Y:2001 04 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,453 $6,000 Implemented
NC0211 # 05 Y:2001 05 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,002 $1,028 Not Implemented
NC0211 # 06 Y:2001 06 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,631 $0 Implemented
NC0211 # 07 Y:2001 07 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,506 $1,239 Not Implemented
NC0211 # 08 Y:2001 08 2001 $5,184 $9,200 Not Implemented
NC0189 # 01 Y:2000 01 2000 ADJUST BURNERS FOR EFFICIENT OPERATION $1,081 $800 Implemented
NC0189 # 02 Y:2000 02 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,257 $180 Not Implemented
NC0189 # 03 Y:2000 03 2000 USE OPTIMUM THICKNESS INSULATION $1,275 $2,668 Not Implemented
NC0189 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,822 $100 Not Implemented
NC0189 # 05 Y:2000 05 2000 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,045 $600 Not Implemented
NC0189 # 06 Y:2000 06 2000 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,905 $15,000 Not Implemented
NC0189 # 07 Y:2000 07 2000 $35,750 $0 Not Implemented
NC0189 # 08 Y:2000 08 2000 $9,564 $17,000 Not Implemented
NC0143 # 01 Y:1998 01 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,467 $700 Implemented
NC0143 # 02 Y:1998 02 1998 $50,294 $280,937 Not Implemented
NC0143 # 03 Y:1998 03 1998 RECOVER WASTE HEAT FROM EQUIPMENT $21,615 $25,600 Not Implemented