Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0545 # 06 Y:2017 | 06 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $545 | $914 | Implemented |
SD0545 # 05 Y:2017 | 05 | 2017 | INSULATE BARE EQUIPMENT | $954 | $449 | Implemented |
SD0545 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $3,536 | $6,060 | Implemented |
SD0545 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,279 | $33,276 | Implemented |
SD0500 # 01 Y:2015 | 01 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $326,647 | $943,500 | Implemented |
SD0500 # 02 Y:2015 | 02 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $105,336 | $417,200 | Implemented |
SD0500 # 06 Y:2015 | 06 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,651 | $500 | Implemented |
SD0500 # 07 Y:2015 | 07 | 2015 | USE PHOTOCELL CONTROLS | $1,308 | $2,775 | Implemented |
SF0378 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,063 | $500 | Implemented |
SF0378 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,697 | $0 | Implemented |
SF0340 # 12 Y:2007 | 12 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,702 | $15,428 | Implemented |
SF0340 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,354 | $0 | Implemented |
SF0340 # 02 Y:2007 | 02 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $12,059 | $320 | Implemented |
SF0340 # 03 Y:2007 | 03 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $6,510 | $0 | Implemented |
SF0340 # 04 Y:2007 | 04 | 2007 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $155,963 | $36,556 | Implemented |
SF0340 # 13 Y:2007 | 13 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,410 | $3,712 | Implemented |
SF0340 # 08 Y:2007 | 08 | 2007 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,828 | $1,892 | Implemented |
SF0340 # 15 Y:2007 | 15 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,697 | $37,793 | Implemented |
SF0340 # 16 Y:2007 | 16 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,354 | $70,400 | Implemented |
SD0252 # 07 Y:2000 | 07 | 2000 | INSTALL SKYLIGHTS | $70,269 | $5,536 | Implemented |
SD0252 # 06 Y:2000 | 06 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,692 | $1,500 | Implemented |
SD0252 # 05 Y:2000 | 05 | 2000 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,167 | $10,200 | Implemented |
SD0252 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,867 | $200 | Implemented |
SD0252 # 03 Y:2000 | 03 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $9,331 | $20,000 | Implemented |
SD0252 # 01 Y:2000 | 01 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $36,908 | $85,000 | Implemented |