Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0458 # 01 Y:2015 | 01 | 2015 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $7,036 | $0 | Implemented |
UM0455 # 06 Y:2015 | 06 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,725 | $25,000 | Not Implemented |
UM0455 # 05 Y:2015 | 05 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,338 | $2,500 | Implemented |
UM0455 # 04 Y:2015 | 04 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,274 | $7,300 | Implemented |
UM0455 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,898 | $500 | Implemented |
UM0455 # 02 Y:2015 | 02 | 2015 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $8,778 | $0 | Not Implemented |
UM0455 # 01 Y:2015 | 01 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,635 | $2,000 | Not Implemented |
UM0350 # 01 Y:2009 | 01 | 2009 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $14,346 | $12,800 | Not Implemented |
UM0350 # 08 Y:2009 | 08 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $649 | $1,200 | Implemented |
UM0350 # 07 Y:2009 | 07 | 2009 | INSULATE BARE EQUIPMENT | $846 | $474 | Not Implemented |
UM0350 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,186 | $10,960 | Not Implemented |
UM0350 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,990 | $100 | Not Implemented |
UM0350 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,744 | $30,000 | Implemented |
UM0350 # 03 Y:2009 | 03 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,300 | $1,500 | Not Implemented |
UM0350 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,487 | $13,000 | Implemented |
UM0190 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,684 | $1,000 | Not Implemented |
UM0190 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $20,286 | $8,250 | Implemented |
UM0190 # 04 Y:2001 | 04 | 2001 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $293,000 | $360,000 | Not Implemented |
UM0190 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $82,700 | $8,000 | Not Implemented |
UM0190 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $20,468 | $9,600 | Not Implemented |
UM0190 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $81,576 | $80,632 | Implemented |
ND0169 # 01 Y:1993 | 01 | 1993 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $49,625 | $65,000 | Not Implemented |
ND0169 # 08 Y:1993 | 08 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $125 | $200 | Not Implemented |
ND0169 # 07 Y:1993 | 07 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $235 | $200 | Not Implemented |
ND0169 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $790 | $430 | Not Implemented |