Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,001

matching recommendations
Reset
SIC 286 Industrial Organic Chemicals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0056 # 05 Y:2003 05 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,571 $5,107 Not Implemented
IC0056 # 06 Y:2003 06 2003 REPAIR AND ELIMINATE STEAM LEAKS $17,396 $3,500 Not Implemented
IC0056 # 07 Y:2003 07 2003 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $7,043 $3,000 Not Implemented
IC0056 # 08 Y:2003 08 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $3,180 $4,206 Not Implemented
IC0056 # 09 Y:2003 09 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $1,770 $2,052 Not Implemented
IC0056 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $2,293 $683 Not Implemented
IC0056 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $1,329 $400 Not Implemented
LL0154 # 01 Y:2003 01 2003 REPAIR AND ELIMINATE STEAM LEAKS $18,488,939 $413,700 n/a
LL0154 # 02 Y:2003 02 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $11,340,034 $773,535 n/a
LL0154 # 03 Y:2003 03 2003 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $6,313,507 $750,000 Not Implemented
LL0154 # 04 Y:2003 04 2003 REDUCE EXCESS STEAM BLEEDING $504,716 $45,360 Not Implemented
LL0154 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $109,742 $60,716 Implemented
LL0154 # 06 Y:2003 06 2003 USE PHOTOCELL CONTROLS $36,675 $4,100 Not Implemented
LL0154 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $11,082 $2,865 Not Implemented
WV0243 # 01 Y:2002 01 2002 INSTALL OCCUPANCY SENSORS $520 $150 Implemented
WV0243 # 02 Y:2002 02 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $38,997 $220 Implemented
WV0243 # 03 Y:2002 03 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $38,007 $550 Implemented
WV0243 # 04 Y:2002 04 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,642 $2,800 Not Implemented
WV0243 # 05 Y:2002 05 2002 REPAIR AND ELIMINATE STEAM LEAKS $45,099 $1,050 Implemented
WV0243 # 06 Y:2002 06 2002 USE PHOTOCELL CONTROLS $1,799 $1,500 Not Implemented
WV0243 # 07 Y:2002 07 2002 INSULATE BARE EQUIPMENT $2,317 $777 Implemented
WV0243 # 08 Y:2002 08 2002 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $8,000 $9,750 Not Implemented
WV0243 # 09 Y:2002 09 2002 MINIMIZE WATER USAGE $8,228 $10,000 Not Implemented
WV0243 # 10 Y:2002 10 2002 UTILIZE OUTSIDE CONTRACTING $87,058 $1,100 Not Implemented
UM0206 # 01 Y:2002 01 2002 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $100,000 $5,000 Not Implemented