Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

103

matching recommendations
Reset
SIC 289 Miscellaneous Chemical Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0871 # 02 Y:2010 02 2010 INCREASE AMOUNT OF CONDENSATE RETURNED $20,114 $23,200 Not Implemented
GT0871 # 01 Y:2010 01 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $2,860 $768 Implemented
GT0854 # 06 Y:2008 06 2008 REDUCE EXCESSIVE BOILER BLOWDOWN $4,690 $0 Not Implemented
GT0854 # 08 Y:2008 08 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $14,260 $23,000 Implemented
GT0854 # 07 Y:2008 07 2008 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,141 $10,000 Not Implemented
GT0854 # 05 Y:2008 05 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,990 $80,000 Not Implemented
GT0854 # 04 Y:2008 04 2008 REPAIR OR REPLACE STEAM TRAPS $25,424 $5,000 Implemented
GT0854 # 03 Y:2008 03 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $5,970 $2,500 Not Implemented
GT0854 # 02 Y:2008 02 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,745 $3,000 Implemented
GT0854 # 01 Y:2008 01 2008 REPAIR AND ELIMINATE STEAM LEAKS $2,568 $700 Implemented
GT0854 # 09 Y:2008 09 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,015 $35,125 Implemented
GT0679 # 06 Y:1999 06 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,006 $46,917 Not Implemented
GT0679 # 05 Y:1999 05 1999 CLOSE OFF UNNEEDED STEAM LINES $164 $50 Implemented
GT0679 # 04 Y:1999 04 1999 INSULATE FEEDWATER TANK $4,877 $5,350 Implemented
GT0679 # 03 Y:1999 03 1999 REPAIR AND ELIMINATE STEAM LEAKS $1,157 $200 Implemented
GT0679 # 02 Y:1999 02 1999 CONVERT COMBUSTION EQUIPMENT TO BURN OIL $27,261 $5,000 Not Implemented
GT0679 # 01 Y:1999 01 1999 COMBINE UTILITY METERS $1,400 $0 Not Implemented
GT0679 # 07 Y:1999 07 1999 $5,625 $14,270 Not Implemented
GT0634 # 05 Y:1998 05 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $932 $3,180 Implemented
GT0634 # 06 Y:1998 06 1998 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,220 $0 Implemented
GT0634 # 07 Y:1998 07 1998 $2,730 $780 Not Implemented
GT0634 # 04 Y:1998 04 1998 COVER OPEN TANKS $80 $300 Implemented
GT0634 # 03 Y:1998 03 1998 REDUCE VENTILATION AIR $1,900 $2,000 Not Implemented
GT0634 # 02 Y:1998 02 1998 INSULATE BARE EQUIPMENT $1,600 $840 Not Implemented
GT0634 # 01 Y:1998 01 1998 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $290 $800 Not Implemented