Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
SIC 2891 Adhesives And Sealants
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0634 # 01 Y:1998 01 1998 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $290 $800 Not Implemented
GT0617 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,314 $7,680 Implemented
GT0617 # 07 Y:1997 07 1997 $125,400 $150,000 Not Implemented
GT0617 # 06 Y:1997 06 1997 IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) $3,175 $2,800 Not Implemented
GT0617 # 05 Y:1997 05 1997 $139,500 $155,000 Not Implemented
GT0617 # 03 Y:1997 03 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,899 $450 Implemented
GT0617 # 02 Y:1997 02 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,920 $2,120 Implemented
GT0617 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $564 $4,997 Not Implemented
GT0579 # 08 Y:1996 08 1996 METER WASTE WATER $1,780 $0 Not Implemented
GT0579 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $784 $3,892 Implemented
GT0579 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $681 $550 Implemented
GT0579 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $844 $200 Implemented
GT0579 # 04 Y:1996 04 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,141 $230 Not Implemented
GT0579 # 05 Y:1996 05 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $835 $1,260 Not Implemented
GT0579 # 06 Y:1996 06 1996 USE RADIANT HEATER FOR SPOT HEATING $1,940 $9,180 Not Implemented
GT0579 # 07 Y:1996 07 1996 RECOVER AND REUSE COOLING WATER $2,311 $2,500 Implemented
GT0527 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $360 $0 Not Implemented
GT0527 # 07 Y:1994 07 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $190 $200 Implemented
GT0527 # 06 Y:1994 06 1994 REPAIR AND ELIMINATE STEAM LEAKS $670 $450 Implemented
GT0527 # 05 Y:1994 05 1994 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $13,000 $15,100 Implemented
GT0527 # 02 Y:1994 02 1994 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $700 $0 Implemented
GT0527 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $880 $3,200 Implemented
GT0527 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $590 $300 Not Implemented
GT0509 # 07 Y:1993 07 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,341 $21,050 Implemented
GT0509 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,569 $450 Implemented