Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
758
matching recommendationsSIC | 2899 | Chemical Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0727 # 02 Y:2006 | 02 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $1,646 | $75 | Implemented |
OK0727 # 03 Y:2006 | 03 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $12,463 | $40,452 | Not Implemented |
OK0727 # 04 Y:2006 | 04 | 2006 | USE GRAVITY FEEDS WHEREVER POSSIBLE | $10,056 | $1,636 | Not Implemented |
OK0727 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,960 | $8,407 | Not Implemented |
OK0727 # 06 Y:2006 | 06 | 2006 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $117,767 | $838,833 | Not Implemented |
OK0727 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $14,689 | $7,635 | Implemented |
OK0727 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $676 | $535 | Not Implemented |
IC0105 # 01 Y:2005 | 01 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $60,808 | $100,000 | Implemented |
IC0105 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,211 | $2,000 | Implemented |
IC0105 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $17,271 | $3,900 | Implemented |
IC0105 # 04 Y:2005 | 04 | 2005 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $12,910 | $900 | Not Implemented |
IC0105 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,728 | $42,000 | Not Implemented |
IC0105 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $94 | $713 | Not Implemented |
IC0105 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $255 | $714 | Not Implemented |
IC0105 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,344 | $13,017 | Not Implemented |
IC0087 # 01 Y:2004 | 01 | 2004 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $210,887 | $2,078 | Not Implemented |
IC0087 # 02 Y:2004 | 02 | 2004 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $135,849 | $18,578 | Not Implemented |
IC0087 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $216,557 | $4,311 | Implemented |
IC0087 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $43,578 | $6,900 | Implemented |
IC0087 # 05 Y:2004 | 05 | 2004 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $53,985 | $1,560 | Not Implemented |
IC0087 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,571 | $8,465 | Implemented |
IC0087 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $28,383 | $56,925 | Implemented |
IC0087 # 08 Y:2004 | 08 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,114 | $609,500 | Not Implemented |
IC0087 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,613 | $104,650 | Not Implemented |
IC0087 # 10 Y:2004 | 10 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,168 | $79,350 | Implemented |