Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
471
matching recommendationsSIC | 295 | Asphalt Paving And Roofing Materials |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0062 # 04 Y:2003 | 04 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $8,560 | $5,280 | Implemented |
IC0062 # 05 Y:2003 | 05 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $45,681 | $10,200 | Implemented |
IC0062 # 06 Y:2003 | 06 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,526 | $21,542 | Implemented |
IC0062 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,470 | $28,470 | Implemented |
IC0062 # 08 Y:2003 | 08 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $75,511 | $20,000 | Implemented |
OR0431 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,830 | $54,571 | Implemented |
IC0061 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $694 | $1,859 | Implemented |
IC0061 # 02 Y:2003 | 02 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $3,861 | $2,640 | Implemented |
LM0048 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,111 | $4,650 | Implemented |
LM0048 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,650 | $951 | Implemented |
LM0048 # 04 Y:2003 | 04 | 2003 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,317 | $3,200 | Implemented |
LM0048 # 05 Y:2003 | 05 | 2003 | RECOVER AND REUSE COOLING WATER | $16,200 | $1,000 | Implemented |
LM0048 # 06 Y:2003 | 06 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $36,400 | $14,567 | Implemented |
LM0048 # 07 Y:2003 | 07 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $25,093 | $15,842 | Implemented |
LM0048 # 09 Y:2003 | 09 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $672,000 | $100,000 | Implemented |
LM0048 # 10 Y:2003 | 10 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $82,232 | $25,000 | Implemented |
LM0048 # 12 Y:2003 | 12 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $351 | $0 | Implemented |
UF0313 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,514 | $1,631 | Implemented |
UF0313 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,785 | $1,826 | Implemented |
UF0313 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $7,223 | $973 | Implemented |
UF0313 # 08 Y:2003 | 08 | 2003 | INSTALL BACK-UP EQUIPMENT | $57,960 | $109,500 | Implemented |
UF0313 # 09 Y:2003 | 09 | 2003 | INSTALL SYSTEM TO COLLECT SCRAP | $1,808 | $700 | Implemented |
OR0418 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,409 | $1,400 | Implemented |
OR0418 # 02 Y:2002 | 02 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $6,865 | $7,600 | Implemented |
OR0418 # 03 Y:2002 | 03 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,090 | $1,800 | Implemented |