Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsSIC | 295 | Asphalt Paving And Roofing Materials |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0241 # 07 Y:2006 | 07 | 2006 | USE SYNTHETIC LUBRICANT | $1,841 | $500 | Not Implemented |
LE0241 # 06 Y:2006 | 06 | 2006 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,629 | $12,033 | Not Implemented |
LE0241 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,395 | $2,500 | Not Implemented |
LE0241 # 04 Y:2006 | 04 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $24,673 | $12,500 | Not Implemented |
LE0241 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $47,697 | $40,000 | Not Implemented |
LE0241 # 02 Y:2006 | 02 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $61,625 | $80,000 | Not Implemented |
LE0241 # 01 Y:2006 | 01 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $306,494 | $200,000 | Not Implemented |
IA0390 # 02 Y:2006 | 02 | 2006 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $13,877 | $850 | Not Implemented |
IA0390 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $453 | $496 | Not Implemented |
IA0390 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $892 | $1,124 | Not Implemented |
IA0390 # 04 Y:2006 | 04 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $8,812 | $3,600 | Implemented |
IA0390 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $146,308 | $18,000 | Not Implemented |
IA0390 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $53,488 | $1,000 | Implemented |
IA0390 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,305 | $896 | Implemented |
LM0111 # 04 Y:2006 | 04 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,249 | $522 | Not Implemented |
LM0111 # 06 Y:2006 | 06 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $650,132 | $0 | Implemented |
LM0111 # 05 Y:2006 | 05 | 2006 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $235,359 | $7,000 | Not Implemented |
LM0111 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $879 | $5,000 | Implemented |
LM0111 # 01 Y:2006 | 01 | 2006 | USE OPTIMUM TEMPERATURE | $1,018 | $0 | Not Implemented |
LM0111 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $2,109 | $3,000 | Implemented |
SF0322 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $19,058 | $11,866 | Implemented |
SF0322 # 03 Y:2006 | 03 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $31 | $29,800 | Implemented |
SF0322 # 05 Y:2006 | 05 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1 | $1,698 | Not Implemented |
SF0322 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19 | $24,854 | Implemented |
SF0322 # 07 Y:2006 | 07 | 2006 | USE PHOTOCELL CONTROLS | $237 | $345 | Implemented |