Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
155
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2206 # 06 Y:2022 | 06 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,272 | $2,688 | Implemented |
LS2206 # 05 Y:2022 | 05 | 2022 | INSTALL OCCUPANCY SENSORS | $21 | $25 | Not Implemented |
LS2206 # 04 Y:2022 | 04 | 2022 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $336 | $250 | Implemented |
LS2206 # 02 Y:2022 | 02 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,014 | $25 | Implemented |
LS2206 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,034 | $630 | Implemented |
LS2206 # 01 Y:2022 | 01 | 2022 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,066 | $10 | Implemented |
LS2103 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,440 | $900 | Implemented |
LS2103 # 01 Y:2021 | 01 | 2021 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $35,907 | $250 | Implemented |
LS2103 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,807 | $428 | Implemented |
LS2103 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,154 | $39,829 | Implemented |
LS2103 # 05 Y:2021 | 05 | 2021 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $209,892 | $1,023,215 | Implemented |
LS2006 # 06 Y:2020 | 06 | 2020 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,553 | $7,413 | Not Implemented |
LS2006 # 01 Y:2020 | 01 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $796 | $300 | Implemented |
LS2006 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,970 | $1,800 | Implemented |
LS2006 # 07 Y:2020 | 07 | 2020 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $9,737 | $81,000 | Not Implemented |
LS2006 # 04 Y:2020 | 04 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $566 | $375 | Implemented |
LS2006 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,740 | $0 | Implemented |
LS2006 # 05 Y:2020 | 05 | 2020 | INSTALL OCCUPANCY SENSORS | $31 | $45 | Not Implemented |
LS2005 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,208 | $17,766 | Not Implemented |
LS2005 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $114 | $50 | Not Implemented |
LS2005 # 05 Y:2020 | 05 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $274 | $0 | Implemented |
LS2005 # 01 Y:2020 | 01 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $2,727 | $300 | Not Implemented |
LS2005 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,560 | $0 | Implemented |
LS2005 # 06 Y:2020 | 06 | 2020 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $225,476 | $1,204,486 | Not Implemented |
AM0613 # 05 Y:2012 | 05 | 2012 | USE PHOTOCELL CONTROLS | $3,000 | $1,000 | Implemented |