IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

17,378

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0449 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $60 $0 Implemented
CO0449 # 06 Y:1999 06 1999 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $18,110 $3,600 Implemented
CO0449 # 07 Y:1999 07 1999 PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) $2,550 $1,100 Implemented
CO0449 # 08 Y:1999 08 1999 USE EVAPORATION TO CONCENTRATE MATERIAL $1,160 $3,300 Implemented
CO0449 # 09 Y:1999 09 1999 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING $8,960 $620 Implemented
ND0336 # 01 Y:1999 01 1999 DEVELOP A REPAIR/REPLACE POLICY $3,558 $7,202 Not Implemented
ND0336 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,941 $4,883 Not Implemented
ND0336 # 03 Y:1999 03 1999 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $729 $125 Not Implemented
ND0336 # 04 Y:1999 04 1999 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $126 $150 Not Implemented
ND0336 # 05 Y:1999 05 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $458 $400 Not Implemented
ND0336 # 06 Y:1999 06 1999 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $73 $90 Not Implemented
ND0336 # 07 Y:1999 07 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,241 $80 Not Implemented
ND0337 # 01 Y:1999 01 1999 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $422 $125 Not Implemented
ND0337 # 02 Y:1999 02 1999 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $598 $600 Not Implemented
ND0337 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $137 $80 Implemented
ND0337 # 04 Y:1999 04 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $50 $87 Implemented
ND0337 # 05 Y:1999 05 1999 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $226 $0 Implemented
ND0337 # 06 Y:1999 06 1999 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,185 $2,271 Implemented
ND0337 # 07 Y:1999 07 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,512 $240 Not Implemented
ND0337 # 08 Y:1999 08 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $282 $640 Implemented
KU0528 # 01 Y:1999 01 1999 USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC $37,560 $66,040 n/a
KU0528 # 02 Y:1999 02 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $17,330 $800 n/a
KU0528 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,110 $20,590 n/a
KU0528 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,290 $920 n/a
KU0528 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $3,690 $4,240 n/a