Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,020
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0316 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,167 | $9,920 | Not Implemented |
ND0316 # 06 Y:1998 | 06 | 1998 | $2,075 | $250 | Not Implemented | |
ND0316 # 07 Y:1998 | 07 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,405 | $250 | Not Implemented |
ND0316 # 08 Y:1998 | 08 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,335 | $600 | Implemented |
ND0316 # 09 Y:1998 | 09 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $794 | $150 | Implemented |
ND0316 # 10 Y:1998 | 10 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $617 | $363 | Implemented |
ND0316 # 11 Y:1998 | 11 | 1998 | INSTALL OCCUPANCY SENSORS | $485 | $400 | Not Implemented |
ND0316 # 12 Y:1998 | 12 | 1998 | CONVERT TO AQUEOUS CLEANING SYSTEM | $393 | $200 | Implemented |
ND0316 # 13 Y:1998 | 13 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $342 | $550 | Not Implemented |
ND0316 # 14 Y:1998 | 14 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $393 | $60 | Implemented |
WV0154 # 01 Y:1998 | 01 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,075 | $2,580 | Not Implemented |
WV0154 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $16,667 | $9,432 | Not Implemented |
WV0154 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $4,282 | $5,130 | Not Implemented |
WV0154 # 04 Y:1998 | 04 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $322 | $482 | Not Implemented |
WV0154 # 05 Y:1998 | 05 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $162 | $550 | Not Implemented |
WV0154 # 06 Y:1998 | 06 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $142 | $220 | Not Implemented |
WV0154 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $670 | $1,525 | Not Implemented |
WV0154 # 08 Y:1998 | 08 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,940 | $550 | Not Implemented |
WV0154 # 09 Y:1998 | 09 | 1998 | $180,000 | $4,000 | Not Implemented | |
IA0207 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $109,522 | $345,000 | Not Implemented |
IA0207 # 02 Y:1998 | 02 | 1998 | $46,000 | $12,000 | Not Implemented | |
IA0207 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,193 | $1,348 | Implemented |
IA0207 # 04 Y:1998 | 04 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,781 | $4,185 | Implemented |
IA0207 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,212 | $82 | Implemented |
IA0207 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $828 | $25 | Implemented |