Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,020
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0328 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $840 | Implemented |
OK0551 # 01 Y:1998 | 01 | 1998 | $898 | $80,000 | Implemented | |
OK0551 # 02 Y:1998 | 02 | 1998 | $29,885 | $0 | Not Implemented | |
OK0551 # 03 Y:1998 | 03 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,224 | $9,700 | Not Implemented |
OK0551 # 04 Y:1998 | 04 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,304 | $0 | Implemented |
OK0551 # 05 Y:1998 | 05 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,522 | $0 | Implemented |
SD0206 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $83,038 | $163,750 | Not Implemented |
SD0206 # 02 Y:1998 | 02 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,837 | $0 | Implemented |
SD0206 # 03 Y:1998 | 03 | 1998 | USE OPTIMUM THICKNESS INSULATION | $2,817 | $1,076 | Implemented |
SD0206 # 04 Y:1998 | 04 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $519 | $1,260 | Implemented |
SD0206 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,374 | $0 | Implemented |
SD0206 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,218 | $8,500 | Implemented |
SD0206 # 07 Y:1998 | 07 | 1998 | $6,426 | $1,275 | Implemented | |
SD0206 # 08 Y:1998 | 08 | 1998 | $157,414 | $12,000 | Implemented | |
SD0203 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $300 | $967 | Not Implemented |
SD0203 # 02 Y:1998 | 02 | 1998 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,776 | $5,635 | Not Implemented |
SD0203 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $758 | $300 | Not Implemented |
SD0203 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $737 | $900 | Not Implemented |
SD0203 # 05 Y:1998 | 05 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,163 | $1,460 | Not Implemented |
SD0203 # 06 Y:1998 | 06 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,250 | $9,630 | Not Implemented |
SD0203 # 07 Y:1998 | 07 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,100 | $9,000 | Not Implemented |
SD0203 # 08 Y:1998 | 08 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $600 | $0 | Implemented |
SD0203 # 09 Y:1998 | 09 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,400 | $8,500 | Implemented |
KU0496 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,990 | $46,170 | Not Implemented |
KU0496 # 02 Y:1998 | 02 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,940 | $8,640 | Not Implemented |