Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
290
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0099 # 01 Y:1990 | 01 | 1990 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $669 | $50 | Implemented |
UD0329 # 01 Y:1990 | 01 | 1990 | OPTIMIZE PLANT POWER FACTOR | $17,856 | $20,000 | Implemented |
OR0099 # 05 Y:1990 | 05 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,167 | $20,751 | Not Implemented |
OR0099 # 04 Y:1990 | 04 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $399 | $1,480 | Not Implemented |
UD0329 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,783 | $7,500 | Implemented |
UD0329 # 03 Y:1990 | 03 | 1990 | BURN WASTE OIL FOR HEAT | $6,067 | $0 | Implemented |
OR0099 # 03 Y:1990 | 03 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $53 | $117 | Not Implemented |
UD0329 # 02 Y:1990 | 02 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,309 | $1,000 | Implemented |
UD0329 # 05 Y:1990 | 05 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,223 | $6,240 | Implemented |
OR0099 # 02 Y:1990 | 02 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $511 | $60 | Implemented |
OK0329 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $57 | Implemented |
OK0330 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $156 | $0 | Implemented |
MA0196 # 07 Y:1990 | 07 | 1990 | USE OPTIMUM TEMPERATURE | $4,435 | $0 | Not Implemented |
MA0196 # 05 Y:1990 | 05 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,134 | $2,460 | Not Implemented |
MA0196 # 04 Y:1990 | 04 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,856 | $0 | Not Implemented |
OK0330 # 04 Y:1990 | 04 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,329 | $450 | Implemented |
MA0196 # 02 Y:1990 | 02 | 1990 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,178 | $2,409 | Not Implemented |
MA0196 # 01 Y:1990 | 01 | 1990 | INSULATE BARE EQUIPMENT | $583 | $381 | Not Implemented |
OK0330 # 01 Y:1990 | 01 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,537 | $16,218 | Not Implemented |
OK0330 # 03 Y:1990 | 03 | 1990 | INSULATE BARE EQUIPMENT | $3,218 | $2,838 | Implemented |
OK0329 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $1,671 | $0 | Implemented |
MA0197 # 07 Y:1990 | 07 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $6,639 | $19,720 | Not Implemented |
WI0104 # 09 Y:1990 | 09 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,766 | $1,600 | Not Implemented |
MA0196 # 09 Y:1990 | 09 | 1990 | INSTALL SET-BACK TIMERS | $65 | $65 | Not Implemented |
MA0196 # 06 Y:1990 | 06 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $65 | $44 | Not Implemented |