Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13,566
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0309 # 13 Y:2005 | 13 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $374 | $0 | Not Implemented |
WV0309 # 14 Y:2005 | 14 | 2005 | RECOVER AND REUSE COOLING WATER | $12,688 | $5,135 | Not Implemented |
GT0797 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,893 | $3,800 | Implemented |
GT0797 # 02 Y:2005 | 02 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,440 | $1,500 | Implemented |
GT0797 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $121,511 | $243,073 | Implemented |
GT0797 # 04 Y:2005 | 04 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,210 | $17,150 | Not Implemented |
GT0797 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,100 | $500 | Implemented |
GT0797 # 06 Y:2005 | 06 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,716 | $400 | Implemented |
GT0797 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,447 | $3,692 | Implemented |
LE0206 # 01 Y:2005 | 01 | 2005 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $135,669 | $50,000 | Not Implemented |
LE0206 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $31,193 | $5,000 | Implemented |
LE0206 # 03 Y:2005 | 03 | 2005 | INSTALL BACK-UP EQUIPMENT | $11,880 | $14,100 | Implemented |
LE0206 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,905 | $2,500 | Not Implemented |
LE0206 # 05 Y:2005 | 05 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,894 | $2,200 | Not Implemented |
LE0206 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $200 | Implemented |
LE0206 # 07 Y:2005 | 07 | 2005 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $63,361 | $382,500 | Not Implemented |
MI0098 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $24,731 | $1,000 | Implemented |
MI0098 # 02 Y:2005 | 02 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $7,463 | $111 | Implemented |
MI0098 # 03 Y:2005 | 03 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,950 | $1,910 | Implemented |
MI0098 # 04 Y:2005 | 04 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,754 | $4,360 | Not Implemented |
MI0098 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $901 | $380 | Implemented |
MI0098 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $301 | $400 | Implemented |
WI0483 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,449 | $18,810 | n/a |
WI0483 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,950 | $10,000 | Not Implemented |
WI0483 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,804 | $500 | Not Implemented |