Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
703
matching recommendationsSIC | 3084 | Plastics Pipe |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0165 # 09 Y:1999 | 09 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $7,875 | $65 | Implemented |
WV0165 # 08 Y:1999 | 08 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,420 | $0 | Implemented |
WV0165 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $2,680 | $6,918 | Implemented |
WV0165 # 05 Y:1999 | 05 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $923 | $1,250 | Not Implemented |
WV0165 # 04 Y:1999 | 04 | 1999 | PAY UTILITY BILLS ON TIME | $1,874 | $0 | Implemented |
WV0165 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,469 | $4,300 | Not Implemented |
WV0165 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,484 | $45 | Not Implemented |
WV0165 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,350 | $100 | Implemented |
OK0576 # 01 Y:1999 | 01 | 1999 | REDUCE EXCESSIVE BOILER BLOWDOWN | $11,368 | $16,000 | Not Implemented |
OK0576 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,672 | $17,813 | Implemented |
OK0576 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $279 | $140 | Implemented |
OK0576 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $228 | $68 | Not Implemented |
OK0576 # 05 Y:1999 | 05 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $22,560 | $40,000 | Implemented |
OK0576 # 06 Y:1999 | 06 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $4,518 | $3,990 | Implemented |
OK0576 # 07 Y:1999 | 07 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $1,939 | $5,000 | Not Implemented |
OR0336 # 01 Y:1999 | 01 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $93,600 | $200,000 | Implemented |
OR0336 # 02 Y:1999 | 02 | 1999 | INSTALL SENSORS TO DETECT DEFECTS | $31,700 | $0 | Implemented |
OR0336 # 03 Y:1999 | 03 | 1999 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $27,050 | $8,200 | Not Implemented |
OR0336 # 04 Y:1999 | 04 | 1999 | OPTIMIZE PLANT POWER FACTOR | $3,716 | $10,200 | Not Implemented |
OR0337 # 01 Y:1999 | 01 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $44,432 | $21,400 | Not Implemented |
OR0337 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,060 | $0 | Implemented |
OR0337 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $9,949 | $13,663 | Implemented |
OR0337 # 04 Y:1999 | 04 | 1999 | USE LESS WASTEFUL PACKAGING | $34,000 | $73,000 | Not Implemented |
OR0337 # 05 Y:1999 | 05 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $11,000 | $28,700 | Implemented |
TN0644 # 01 Y:1998 | 01 | 1998 | AVOID CONTAMINATION OF END PIECES AND REUSE AS FEED STOCK | $363,750 | $20,000 | Not Implemented |