Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
405
matching recommendationsSIC | 3085 | Plastics Bottles |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0412 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140,256 | $442,314 | Implemented |
NC0412 # 02 Y:2010 | 02 | 2010 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $25,289 | $50 | Implemented |
NC0412 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,233 | $100 | Implemented |
NC0412 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $2,841 | $4,995 | Implemented |
NC0412 # 05 Y:2010 | 05 | 2010 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $7,153 | $15,100 | Implemented |
NC0412 # 07 Y:2010 | 07 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,402 | $1,200 | Implemented |
GT0873 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,353 | $0 | Implemented |
GT0873 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $3,777 | $10,640 | Implemented |
GT0873 # 05 Y:2010 | 05 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $816 | $4,400 | Implemented |
GT0873 # 06 Y:2010 | 06 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,661 | $775 | Implemented |
TT0049 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,756 | $173,505 | Implemented |
MZ0045 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,876 | $46,050 | Implemented |
MZ0045 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,734 | $950 | Implemented |
MZ0045 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,645 | $0 | Implemented |
MZ0045 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $23,660 | $0 | Implemented |
MZ0017 # 01 Y:2008 | 01 | 2008 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $8,697 | $1,600 | Implemented |
MZ0017 # 03 Y:2008 | 03 | 2008 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $13,980 | $15,763 | Implemented |
UD0756 # 01 Y:2007 | 01 | 2007 | USE POWER DURING OFF-PEAK PERIODS | $58,368 | $0 | Implemented |
UD0756 # 02 Y:2007 | 02 | 2007 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $54,790 | $0 | Implemented |
UD0756 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,822 | $18,000 | Implemented |
UD0756 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,237 | $86,570 | Implemented |
UD0756 # 06 Y:2007 | 06 | 2007 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $30,653 | $5,000 | Implemented |
UD0756 # 10 Y:2007 | 10 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,180 | $12,000 | Implemented |
UD0756 # 12 Y:2007 | 12 | 2007 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $4,769 | $0 | Implemented |
UD0756 # 13 Y:2007 | 13 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,160 | $4,680 | Implemented |