Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
162
matching recommendationsSIC | 3087 | Custom Compound Purchased Resins |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0417 # 09 Y:2010 | 09 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,334 | $1,500 | Implemented |
UD0795 # 01 Y:2009 | 01 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $40,310 | $0 | Implemented |
UD0795 # 05 Y:2009 | 05 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $2,905 | $500 | Implemented |
UD0795 # 08 Y:2009 | 08 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,781 | $0 | Implemented |
UD0795 # 13 Y:2009 | 13 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $768 | $0 | Implemented |
LE0264 # 01 Y:2007 | 01 | 2007 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $25,680 | $50,000 | Implemented |
LE0264 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,103 | $2,500 | Implemented |
LE0264 # 03 Y:2007 | 03 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $4,204 | $2,000 | Implemented |
LE0264 # 05 Y:2007 | 05 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,084 | $500 | Implemented |
LE0264 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,184 | $2,500 | Implemented |
LE0264 # 10 Y:2007 | 10 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,288 | $1,000 | Implemented |
UM0324 # 05 Y:2007 | 05 | 2007 | OPTIMIZE PLANT POWER FACTOR | $7,222 | $6,917 | Implemented |
UM0324 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,978 | $0 | Implemented |
UD0753 # 02 Y:2007 | 02 | 2007 | REDUCE VENTILATION AIR | $67,600 | $19,800 | Implemented |
UD0753 # 11 Y:2007 | 11 | 2007 | USE OPTIMUM TEMPERATURE | $998 | $0 | Implemented |
UD0753 # 01 Y:2007 | 01 | 2007 | DEVELOP STANDARD OPERATING PROCEDURES | $98,450 | $3,040 | Implemented |
UD0753 # 09 Y:2007 | 09 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,816 | $0 | Implemented |
UD0753 # 06 Y:2007 | 06 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $10,800 | $15,600 | Implemented |
UD0753 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $11,994 | $7,875 | Implemented |
UD0753 # 07 Y:2007 | 07 | 2007 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $8,390 | $15,000 | Implemented |
LE0217 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,764 | $900 | Implemented |
LE0217 # 02 Y:2005 | 02 | 2005 | KEEP EQUIPMENT CLEAN | $28,000 | $840 | Implemented |
LE0217 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,158 | $900 | Implemented |
LE0217 # 08 Y:2005 | 08 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,372 | $263 | Implemented |
LE0217 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $16,487 | $6,845 | Implemented |