Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

169

matching recommendations
Reset
SIC 3089 Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DS0139 # 06 Y:1999 06 1999 $2,633 $7,000 Implemented
UL0219 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $563 $20 Implemented
UL0219 # 02 Y:1999 02 1999 OPTIMIZE PLANT POWER FACTOR $8,356 $24,627 Implemented
UL0219 # 03 Y:1999 03 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $191 $0 Implemented
UL0219 # 04 Y:1999 04 1999 METER WASTE WATER $4,053 $0 Implemented
UL0219 # 05 Y:1999 05 1999 $2,520 $300 Implemented
UL0219 # 06 Y:1999 06 1999 $4,514 $60 Implemented
CO0435 # 02 Y:1999 02 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,380 $2,000 Implemented
CO0435 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $370 $500 Implemented
CO0435 # 05 Y:1999 05 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $310 $100 Implemented
CO0435 # 06 Y:1999 06 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $210 $134 Implemented
ND0320 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $131 $0 Implemented
ND0320 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $695 $1,893 Implemented
ND0320 # 03 Y:1999 03 1999 USE PHOTOCELL CONTROLS $303 $600 Implemented
ND0320 # 04 Y:1999 04 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $737 $255 Implemented
ND0320 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $320 $80 Implemented
ND0320 # 06 Y:1999 06 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $451 $455 Implemented
KU0513 # 01 Y:1999 01 1999 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $166,610 $85,440 Implemented
KU0513 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,800 $700 Implemented
KU0513 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $3,080 $4,830 Implemented
KU0513 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $950 $1,000 Implemented
KU0513 # 06 Y:1999 06 1999 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $1,250 $1,000 Implemented
KU0513 # 07 Y:1999 07 1999 $23,400 $61,400 Implemented
MS0131 # 03 Y:1999 03 1999 INSTALL TIMERS AND/OR THERMOSTATS $146 $236 Implemented
MS0131 # 05 Y:1999 05 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,970 $0 Implemented