Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
339
matching recommendationsSIC | 3089 | Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0120 # 04 Y:2001 | 04 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,925 | $7,125 | Not Implemented |
LL0120 # 03 Y:2001 | 03 | 2001 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $205,089 | $425,809 | n/a |
LL0120 # 02 Y:2001 | 02 | 2001 | USE PHOTOCELL CONTROLS | $8,053 | $110 | Implemented |
LL0120 # 01 Y:2001 | 01 | 2001 | INSULATE BARE EQUIPMENT | $165,697 | $5,304 | Implemented |
UD0633 # 09 Y:2001 | 09 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,094 | $180 | Not Implemented |
UD0633 # 08 Y:2001 | 08 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,374 | $0 | Implemented |
UD0633 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,150 | $1,750 | Implemented |
UD0633 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,155 | $5,550 | Not Implemented |
UD0633 # 05 Y:2001 | 05 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,373 | $600 | Implemented |
UD0633 # 04 Y:2001 | 04 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,223 | $4,000 | Not Implemented |
UD0633 # 01 Y:2001 | 01 | 2001 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $25,095 | $6,000 | Implemented |
UD0633 # 02 Y:2001 | 02 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $17,974 | $3,000 | Implemented |
UD0633 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $10,072 | $1,560 | Not Implemented |
SU0125 # 08 Y:2001 | 08 | 2001 | OPTIMIZE PLANT POWER FACTOR | $4,470 | $6,200 | Implemented |
SU0125 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $2,096 | $665 | Not Implemented |
SU0125 # 11 Y:2001 | 11 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,719 | $760 | Implemented |
SU0125 # 10 Y:2001 | 10 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,216 | $9,990 | Not Implemented |
SU0125 # 01 Y:2001 | 01 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,561 | $0 | Implemented |
SU0125 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,467 | $0 | Implemented |
SU0125 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,122 | $20,070 | Implemented |
SU0125 # 07 Y:2001 | 07 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $920 | $3,275 | Not Implemented |
SU0125 # 09 Y:2001 | 09 | 2001 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $34,312 | $0 | Implemented |
SU0125 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,687 | $342 | Not Implemented |
SU0125 # 06 Y:2001 | 06 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,313 | $840 | Not Implemented |
IA0275 # 07 Y:2001 | 07 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,067 | $0 | Implemented |