Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

58

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0504 # 05 Y:2006 05 2006 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $23,000 $0 Implemented
OR0504 # 01 Y:2006 01 2006 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $64,300 $20,000 Implemented
OR0504 # 02 Y:2006 02 2006 REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS $22,500 $44,500 Implemented
WV0348 # 01 Y:2006 01 2006 PREHEAT COMBUSTION AIR WITH WASTE HEAT $22,813 $25,350 Implemented
WV0348 # 02 Y:2006 02 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $14,538 $3,000 Implemented
WV0348 # 16 Y:2006 16 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $545 $266 Implemented
WV0348 # 15 Y:2006 15 2006 DEVELOP A REPAIR/REPLACE POLICY $866 $680 Implemented
WV0348 # 14 Y:2006 14 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,057 $390 Implemented
WV0348 # 04 Y:2006 04 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,642 $8,678 Implemented
WV0348 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,260 $0 Implemented
WV0348 # 08 Y:2006 08 2006 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,808 $1,000 Implemented
WV0348 # 10 Y:2006 10 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,322 $560 Implemented
CO0587 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,050 $14,465 Implemented
CO0587 # 05 Y:2006 05 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $54 $171 Implemented
CO0587 # 04 Y:2006 04 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $400 $400 Implemented
CO0587 # 01 Y:2006 01 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $4,250 $4,140 Implemented
CO0587 # 03 Y:2006 03 2006 REPAIR AND ELIMINATE STEAM LEAKS $3,370 $650 Implemented
CO0587 # 02 Y:2006 02 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,000 $270 Implemented
MI0136 # 01 Y:2006 01 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $36,851 $40,224 Implemented
MI0136 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,741 $1,074 Implemented
MI0136 # 05 Y:2006 05 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,760 $0 Implemented
MI0136 # 06 Y:2006 06 2006 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,680 $100 Implemented
SU0238 # 10 Y:2006 10 2006 INSTALL OCCUPANCY SENSORS $86 $127 Implemented
SU0238 # 05 Y:2006 05 2006 DISCONNECT BALLASTS $788 $0 Implemented
SU0238 # 02 Y:2006 02 2006 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $55,282 $0 Implemented