Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
278
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0135 # 05 Y:1999 | 05 | 1999 | $55,250 | $162,750 | Not Implemented | |
AS0262 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,548 | $100 | Implemented |
AS0262 # 02 Y:1999 | 02 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,369 | $1,700 | Implemented |
AS0262 # 03 Y:1999 | 03 | 1999 | USE SYNTHETIC LUBRICANT | $1,269 | $2,378 | Not Implemented |
AS0262 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,402 | $120 | Not Implemented |
AS0262 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,565 | $3,139 | Not Implemented |
AS0262 # 06 Y:1999 | 06 | 1999 | METER WASTE WATER | $2,057 | $5,000 | Not Implemented |
AS0262 # 08 Y:1999 | 08 | 1999 | $11,081 | $25,000 | Not Implemented | |
GT0672 # 06 Y:1999 | 06 | 1999 | USE POWER DURING OFF-PEAK PERIODS | $32,520 | $0 | Implemented |
GT0672 # 04 Y:1999 | 04 | 1999 | FILTER AND REUSE HYDRAULIC OIL | $1,950 | $3,500 | Not Implemented |
GT0672 # 01 Y:1999 | 01 | 1999 | REDUCE FLUID FLOW RATES | $4,090 | $600 | Implemented |
GT0672 # 03 Y:1999 | 03 | 1999 | MAINTAIN MACHINES TO REDUCE LEAKS | $6,500 | $5,000 | Implemented |
GT0672 # 02 Y:1999 | 02 | 1999 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $9,897 | $5,660 | Not Implemented |
GT0672 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,071 | $51,281 | Implemented |
AS0259 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $242 | $240 | Not Implemented |
AS0259 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $155 | $100 | Not Implemented |
AS0259 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $623 | $1,400 | Not Implemented |
AS0259 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,440 | $3,500 | Not Implemented |
AS0259 # 05 Y:1999 | 05 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $2,717 | $120 | Not Implemented |
AS0259 # 06 Y:1999 | 06 | 1999 | RECOVER AND REUSE COOLING WATER | $27 | $38 | Not Implemented |
AS0259 # 07 Y:1999 | 07 | 1999 | $34,440 | $1,220 | Not Implemented | |
ND0332 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,688 | $750 | Not Implemented |
ND0332 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,668 | $500 | Implemented |
ND0332 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,580 | $480 | Implemented |
ND0332 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $-61 | $1,560 | Not Implemented |