Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

249

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0055 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,109 $1,536 Not Implemented
OD0055 # 06 Y:1996 06 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $980 $500 Not Implemented
OD0055 # 07 Y:1996 07 1996 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $388 $240 Not Implemented
OD0055 # 08 Y:1996 08 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $158 $0 Not Implemented
OK0491 # 01 Y:1996 01 1996 BURN WASTE OIL FOR HEAT $1,349 $2,995 Not Implemented
OK0491 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,329 $30 Implemented
OK0491 # 03 Y:1996 03 1996 USE OPTIMUM THICKNESS INSULATION $12,771 $37,950 Implemented
OK0491 # 04 Y:1996 04 1996 REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS $9,832 $27,000 Not Implemented
OK0491 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $329 $655 Implemented
OK0491 # 06 Y:1996 06 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $234 $400 Implemented
OK0491 # 07 Y:1996 07 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $109 $62 Implemented
MA0359 # 01 Y:1996 01 1996 INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS $9,520 $17,800 Not Implemented
MA0359 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,359 $13,344 Not Implemented
MA0359 # 03 Y:1996 03 1996 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $5,436 $6,000 Not Implemented
MA0359 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $933 $1,440 Not Implemented
MA0359 # 05 Y:1996 05 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $830 $0 Not Implemented
MA0359 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $604 $350 Not Implemented
UF0138 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $683 $389 Not Implemented
UF0138 # 02 Y:1996 02 1996 USE PHOTOCELL CONTROLS $1,801 $3,600 Not Implemented
UF0138 # 03 Y:1996 03 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $840 $0 Not Implemented
UF0138 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $956 $3,206 Not Implemented
UF0138 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,918 $350 Not Implemented
UF0138 # 06 Y:1996 06 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $4,056 $0 Not Implemented
UF0138 # 07 Y:1996 07 1996 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $19,398 $2,500 Not Implemented
WV0084 # 01 Y:1996 01 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,160 $800 Implemented