Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
141
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0713 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,594 | $4,336 | Implemented |
OR0713 # 06 Y:2018 | 06 | 2018 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $929 | $0 | Implemented |
OR0713 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,959 | $10,959 | Implemented |
OR0713 # 04 Y:2018 | 04 | 2018 | UPGRADE CONTROLS ON COMPRESSORS | $7,018 | $26,371 | Implemented |
OR0713 # 05 Y:2018 | 05 | 2018 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,108 | $5,028 | Implemented |
OR0713 # 01 Y:2018 | 01 | 2018 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $219,819 | $375,000 | Not Implemented |
AM0765 # 06 Y:2018 | 06 | 2018 | INSTALL OCCUPANCY SENSORS | $510 | $595 | Implemented |
AM0765 # 05 Y:2018 | 05 | 2018 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,740 | $0 | Implemented |
AM0765 # 04 Y:2018 | 04 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,210 | $22 | Not Implemented |
AM0765 # 03 Y:2018 | 03 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,060 | $1,000 | Implemented |
AM0765 # 02 Y:2018 | 02 | 2018 | OPTIMIZE PLANT POWER FACTOR | $71,530 | $81,610 | Implemented |
AM0765 # 01 Y:2018 | 01 | 2018 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $173,300 | $721,800 | Not Implemented |
NC0616 # 08 Y:2018 | 08 | 2018 | REDESIGN PROCESS | $36,741 | $2,500 | Implemented |
NC0616 # 10 Y:2018 | 10 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,190 | $500 | Not Implemented |
NC0616 # 07 Y:2018 | 07 | 2018 | INSTALL SENSORS TO DETECT DEFECTS | $112,500 | $150,000 | Implemented |
NC0616 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $505 | $50 | Implemented |
NC0616 # 04 Y:2018 | 04 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,380 | $20,000 | Not Implemented |
NC0616 # 06 Y:2018 | 06 | 2018 | REDESIGN PROCESS | $7,804 | $10,000 | Not Implemented |
NC0616 # 05 Y:2018 | 05 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,999 | $100 | Implemented |
NC0616 # 02 Y:2018 | 02 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,695 | $225 | Implemented |
NC0616 # 09 Y:2018 | 09 | 2018 | AVOID REWINDING MOTORS MORE THAN TWICE | $2,586 | $5,865 | Implemented |
NC0616 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,771 | $43,490 | Implemented |
BS0115 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,604 | $144 | Not Implemented |
BS0115 # 06 Y:2018 | 06 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,334 | $1,920 | Not Implemented |
BS0115 # 07 Y:2018 | 07 | 2018 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $23,770 | $8,000 | Not Implemented |